Accurate Post-Calibration Predictions for Noninvasive Glucose Measurements in People Using Confocal Raman Spectroscopy.


ABSTRACT: In diabetes prevention and care, invasiveness of glucose measurement impedes efficient therapy and hampers the identification of people at risk. Lack of calibration stability in non-invasive technology has confined the field to short-term proof of principle. Addressing this challenge, we demonstrate the first practical use of a Raman-based and portable non-invasive glucose monitoring device used for at least 15 days following calibration. In a home-based clinical study involving 160 subjects with diabetes, the largest of its kind to our knowledge, we find that the measurement accuracy is insensitive to age, sex, and skin color. A subset of subjects with type 2 diabetes highlights promising real-life results with 99.8% of measurements within A + B zones in the consensus error grid and a mean absolute relative difference of 14.3%. By overcoming the problem of calibration stability, we remove the lingering uncertainty about the practical use of non-invasive glucose monitoring, boding a new, non-invasive era in diabetes monitoring.

SUBMITTER: Pors A 

PROVIDER: S-EPMC10043934 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accurate Post-Calibration Predictions for Noninvasive Glucose Measurements in People Using Confocal Raman Spectroscopy.

Pors Anders A   Rasmussen Kaspar G KG   Inglev Rune R   Jendrike Nina N   Philipps Amalie A   Ranjan Ajenthen G AG   Vestergaard Vibe V   Henriksen Jan E JE   Nørgaard Kirsten K   Freckmann Guido G   Hepp Karl D KD   Gerstenberg Michael C MC   Weber Anders A  

ACS sensors 20230306 3


In diabetes prevention and care, invasiveness of glucose measurement impedes efficient therapy and hampers the identification of people at risk. Lack of calibration stability in non-invasive technology has confined the field to short-term proof of principle. Addressing this challenge, we demonstrate the first practical use of a Raman-based and portable non-invasive glucose monitoring device used for at least 15 days following calibration. In a home-based clinical study involving 160 subjects wit  ...[more]

Similar Datasets

| S-EPMC3162621 | biostudies-other
| S-EPMC10900511 | biostudies-literature
| S-EPMC11780617 | biostudies-literature
| S-EPMC7710741 | biostudies-literature
| S-EPMC5345116 | biostudies-literature
| S-EPMC2299220 | biostudies-literature
| S-EPMC10561280 | biostudies-literature
| S-EPMC4463591 | biostudies-literature
| S-EPMC4471954 | biostudies-literature
| S-EPMC9874663 | biostudies-literature