Source Control of Gram-Negative Bacteria Using Self-Disinfecting Sinks in a Swedish Burn Centre.


ABSTRACT: Several retrospective studies have identified hospital sinks as reservoirs of Gram-negative bacteria. The aim of this study was to prospectively investigate the bacterial transmission from sinks to patients and if self-disinfecting sinks could reduce this risk. Samples were collected weekly from sinks (self-disinfecting, treated with boiling water, not treated) and patients in the Burn Centre at Linköping University Hospital, Sweden. The antibiotic susceptibility of Gram-negative isolates was tested, and eight randomly chosen patient isolates and their connected sink isolates were subjected to whole genome sequencing (WGS). Of 489 sink samples, 232 (47%) showed growth. The most frequent findings were Stenotrophomonas maltophilia (n = 130), Pseudomonas aeruginosa (n = 128), and Acinetobacter spp. (n = 55). Bacterial growth was observed in 20% of the samplings from the self-disinfecting sinks and in 57% from the sinks treated with boiling water (p = 0.0029). WGS recognized one transmission of Escherichia coli sampled from an untreated sink to a patient admitted to the same room. In conclusion, the results showed that sinks can serve as reservoirs of Gram-negative bacteria and that self-disinfecting sinks can reduce the transmission risk. Installing self-disinfecting sinks in intensive care units is an important measure in preventing nosocomial infection among critically ill patients.

SUBMITTER: Gideskog M 

PROVIDER: S-EPMC10143680 | biostudies-literature | 2023 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Source Control of Gram-Negative Bacteria Using Self-Disinfecting Sinks in a Swedish Burn Centre.

Gideskog Maria M   Falkeborn Tina T   Welander Jenny J   Melhus Åsa Å  

Microorganisms 20230407 4


Several retrospective studies have identified hospital sinks as reservoirs of Gram-negative bacteria. The aim of this study was to prospectively investigate the bacterial transmission from sinks to patients and if self-disinfecting sinks could reduce this risk. Samples were collected weekly from sinks (self-disinfecting, treated with boiling water, not treated) and patients in the Burn Centre at Linköping University Hospital, Sweden. The antibiotic susceptibility of Gram-negative isolates was te  ...[more]

Similar Datasets

| S-EPMC9487463 | biostudies-literature
| S-EPMC8737083 | biostudies-literature
| PRJNA306133 | ENA
| PRJNA388450 | ENA
| PRJNA311932 | ENA
| PRJNA668381 | ENA
| PRJNA594823 | ENA
| PRJNA1076895 | ENA
| S-EPMC9687006 | biostudies-literature
| PRJNA812595 | ENA