Unknown

Dataset Information

0

A MHz X-ray diffraction set-up for dynamic compression experiments in the diamond anvil cell.


ABSTRACT: An experimental platform for dynamic diamond anvil cell (dDAC) research has been developed at the High Energy Density (HED) Instrument at the European X-ray Free Electron Laser (European XFEL). Advantage was taken of the high repetition rate of the European XFEL (up to 4.5 MHz) to collect pulse-resolved MHz X-ray diffraction data from samples as they are dynamically compressed at intermediate strain rates (≤103 s-1), where up to 352 diffraction images can be collected from a single pulse train. The set-up employs piezo-driven dDACs capable of compressing samples in ≥340 µs, compatible with the maximum length of the pulse train (550 µs). Results from rapid compression experiments on a wide range of sample systems with different X-ray scattering powers are presented. A maximum compression rate of 87 TPa s-1 was observed during the fast compression of Au, while a strain rate of ∼1100 s-1 was achieved during the rapid compression of N2 at 23 TPa s-1.

SUBMITTER: Husband RJ 

PROVIDER: S-EPMC10325015 | biostudies-literature | 2023 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

A MHz X-ray diffraction set-up for dynamic compression experiments in the diamond anvil cell.

Husband Rachel J RJ   Strohm Cornelius C   Appel Karen K   Ball Orianna B OB   Briggs Richard R   Buchen Johannes J   Cerantola Valerio V   Chariton Stella S   Coleman Amy L AL   Cynn Hyunchae H   Dattelbaum Dana D   Dwivedi Anand A   Eggert Jon H JH   Ehm Lars L   Evans William J WJ   Glazyrin Konstantin K   Goncharov Alexander F AF   Graafsma Heinz H   Howard Alex A   Huston Larissa L   Hutchinson Trevor M TM   Hwang Huijeong H   Jacob Sony S   Kaa Johannes J   Kim Jaeyong J   Kim Minseob M   Koemets Egor E   Konôpková Zuzana Z   Langenhorst Falko F   Laurus Torsten T   Li Xinyang X   Mainberger Jona J   Marquardt Hauke H   McBride Emma E EE   McGuire Christopher C   McHardy James D JD   McMahon Malcolm I MI   McWilliams R Stewart RS   Méndez Alba S J ASJ   Mondal Anshuman A   Morard Guillaume G   O'Bannon Earl F EF   Otzen Christoph C   Pépin Charles M CM   Prakapenka Vitali B VB   Prescher Clemens C   Preston Thomas R TR   Redmer Ronald R   Roeper Michael M   Sanchez-Valle Carmen C   Smith Dean D   Smith Raymond F RF   Sneed Daniel D   Speziale Sergio S   Spitzbart Tobias T   Stern Stephan S   Sturtevant Blake T BT   Sztuk-Dambietz Jolanta J   Talkovski Peter P   Velisavljevic Nenad N   Vennari Cara C   Wu Zhongyan Z   Yoo Choong Shik CS   Zastrau Ulf U   Jenei Zsolt Z   Liermann Hanns Peter HP  

Journal of synchrotron radiation 20230615 Pt 4


An experimental platform for dynamic diamond anvil cell (dDAC) research has been developed at the High Energy Density (HED) Instrument at the European X-ray Free Electron Laser (European XFEL). Advantage was taken of the high repetition rate of the European XFEL (up to 4.5 MHz) to collect pulse-resolved MHz X-ray diffraction data from samples as they are dynamically compressed at intermediate strain rates (≤10<sup>3</sup> s<sup>-1</sup>), where up to 352 diffraction images can be collected from  ...[more]

Similar Datasets

| S-EPMC6998780 | biostudies-literature
| S-EPMC5828636 | biostudies-literature
| S-EPMC11405754 | biostudies-literature
| S-EPMC8244043 | biostudies-literature
| S-EPMC9568586 | biostudies-literature
| S-EPMC4856139 | biostudies-literature
| S-EPMC10325027 | biostudies-literature
| S-EPMC4756333 | biostudies-other
| S-EPMC8127375 | biostudies-literature
| S-EPMC7924226 | biostudies-literature