One center experience with a personalized frozen-thawed embryo transfer in patients with recurrent implantation failure.


ABSTRACT:

Purpose

Displaced endometrial receptivity has been discussed as a possible cause of recurrent implantation failure in patients undergoing assisted reproductive technology. The aim of this study was to document our experience with the endometrial receptivity analysis in patients with recurrent implantation failure.

Methods

This retrospective cohort study, conducted at the Fertility Centre of the University Hospital, Duesseldorf Germany, presents the results of the endometrial receptivity analysis in 67 patients with recurrent implantation failure and compares the clinical outcome between these 67 patients who underwent a personalized frozen-thawed embryo transfer guided by the results of the endometrial receptivity analysis and 32 patients with recurrent implantation failure who performed a standardized frozen-thawed embryo transfer.

Results

The data analysis revealed a displaced endometrial receptivity in 73% (49/67) of all tested patients. Out of these patients, 24% (12/49) were early receptive, 74% (36/49) were pre-receptive, and 2% (1/49) were post-receptive. Comparison of pregnancy rate, clinical pregnancy rate, and live-birth rate between personalized (49%, 39%, 27%, respectively) and standardized embryo transfer (44%, 31%, 19%, respectively) reveals no statistically significant difference. In both groups, patients had an average of four unsuccessful embryo transfers.

Conclusion

In this cohort of patients with recurrent implantation failure, the endometrial receptivity analysis showed a high incidence of displaced endometrial receptivity. However, a personalized embryo transfer did not increase reproductive outcome. Displaced endometrial receptivity might not be the main cause for recurrent implantation failure in this cohort.

SUBMITTER: Edimiris P 

PROVIDER: S-EPMC10352213 | biostudies-literature | 2023 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

One center experience with a personalized frozen-thawed embryo transfer in patients with recurrent implantation failure.

Edimiris Philippos P   Doehmen Cornelius C   Baston-Buest Dunja Maria DM   Kruessel Jan-Steffen JS   Bielfeld Alexandra Petra AP  

Journal of assisted reproduction and genetics 20230601 7


<h4>Purpose</h4>Displaced endometrial receptivity has been discussed as a possible cause of recurrent implantation failure in patients undergoing assisted reproductive technology. The aim of this study was to document our experience with the endometrial receptivity analysis in patients with recurrent implantation failure.<h4>Methods</h4>This retrospective cohort study, conducted at the Fertility Centre of the University Hospital, Duesseldorf Germany, presents the results of the endometrial recep  ...[more]

Similar Datasets

| S-EPMC8904980 | biostudies-literature
| S-EPMC10955253 | biostudies-literature
| S-EPMC7488450 | biostudies-literature
| S-EPMC10224903 | biostudies-literature
| S-EPMC6541721 | biostudies-literature
| S-EPMC9436139 | biostudies-literature
| S-EPMC11439401 | biostudies-literature
| S-EPMC8551612 | biostudies-literature
| S-EPMC11348591 | biostudies-literature
| S-EPMC9863254 | biostudies-literature