Unknown

Dataset Information

0

Multiscale morphological analysis of bone microarchitecture around Mg-10Gd implants


ABSTRACT: The utilization of biodegradable magnesium (Mg)-based implants for restoration of bone function following trauma represents a transformative approach in orthopaedic application. One such alloy, magnesium-10 weight percent gadolinium (Mg-10Gd), has been specifically developed to address the rapid degradation of Mg while enhancing its mechanical properties to promote bone healing. Previous studies have demonstrated that Mg-10Gd exhibits favorable osseointegration; however, it exhibits distinct ultrastructural adaptation in comparison to conventional implants like titanium (Ti). A crucial aspect that remains unexplored is the impact of Mg-10Gd degradation on the bone microarchitecture. To address this, we employed hierarchical three-dimensional imaging using synchrotron radiation in conjunction with image-based finite element modelling. By using the methods outlined, the vascular porosity, lacunar porosity and the lacunar-canaliculi network (LCN) morphology of bone around Mg-10Gd in comparison to Ti in a rat model from 4 weeks to 20 weeks post-implantation was investigated. Our investigation revealed that within our observation period, the degradation of Mg-10Gd implants was associated with significantly lower (p < 0.05) lacunar density in the surrounding bone, compared to Ti. Remarkably, the LCN morphology and the fluid flow analysis did not significantly differ for both implant types. In summary, a more pronounced lower lacunae distribution rather than their morphological changes was detected in the surrounding bone upon the degradation of Mg-10Gd implants. This implies potential disparities in bone remodelling rates when compared to Ti implants. Our findings shed light on the intricate relationship between Mg-10Gd degradation and bone microarchitecture, contributing to a deeper understanding of the implications for successful osseointegration. Graphical abstract Image 1 Highlights • Impact of Mg-10Gd implants on vascular porosity and LCN is assessed in comparison to standard Ti implants for the first time.• Multiscale imaging and image-based fluid flow simulation were utilized to study the vascular porosity and LCN.• Significantly lower lacunar distribution was observed in bone around Mg-10Gd compared to Ti implants.

SUBMITTER: Sefa S 

PROVIDER: S-EPMC10412723 | biostudies-literature | 2023 Aug

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6916116 | biostudies-literature
| PRJNA671150 | ENA
| PRJNA671151 | ENA
| S-EPMC5518974 | biostudies-literature
| S-EPMC7178084 | biostudies-literature
| S-EPMC6451400 | biostudies-literature
| S-EPMC8643410 | biostudies-literature
| S-EPMC9960336 | biostudies-literature
| S-EPMC3990776 | biostudies-literature