Unknown

Dataset Information

0

Factors associated with choroidal microvascular dropout change.


ABSTRACT:

Background/aims

To investigate the factors associated with choroidal microvasculature drop-out (MvD) enlargement detected by optical coherence tomography angiography (OCT-A) in glaucomatous eyes.

Methods

Ninety-one eyes of 68 primary open-angle glaucoma patients were enrolled. Only eyes with a minimum of four good quality OCT-A and OCT scans of the optic nerve head acquired at least and with a minimum of 2 years follow-up were included. Area and angular circumference of MvD were analysed on en face images. Univariable and multivariable mixed effects models were constructed to identify the factors contributing to MvD area and angular circumference change over time.

Results

Peripapillary MvD was detected in 53 (58.2%) eyes at baseline and in an additional 17 (18.6%) eyes during follow-up, whereas MvD was not detected in 21 (23.0 %) eyes during the entire follow-up period. In multivariable analysis, worse baseline visual field (VF) mean deviation (MD) (ß=0.27, 95% CI 0.10 to 0.44, p=0.002), greater intraocular pressure (IOP) fluctuations (ß=0.86, 95% CI 0.24 to 1.48, p=0.007), higher peak IOP (ß=0.17, 95% CI -0.01 to 0.35, p=0.067) and greater number of IOP lowering medications (ß=1.36, 95% CI 0.67 to 2.05, p<0.001) were associated with faster MvD area enlargement. Worse baseline VF MD and greater IOP fluctuation were also associated with significantly faster MvD circumferential enlargement in multivariable models.

Conclusion

Greater IOP fluctuation, higher peak IOP, worse baseline VF MD and greater number of glaucoma medications were significantly associated with MvD enlargement in glaucomatous eyes. The identification of factors associated with MvD enlargement may improve our understanding of the role of choroidal vasculature in glaucoma.

SUBMITTER: Micheletti E 

PROVIDER: S-EPMC10464525 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Factors associated with choroidal microvascular dropout change.

Micheletti Eleonora E   Moghimi Sasan S   Nishida Takashi T   El-Nimri Nevin N   Mahmoudinedzah Golnoush G   Kamalipour Alireza A   Mohammadzadeh Vahid V   Zangwill Linda M LM   Weinreb Robert N RN  

The British journal of ophthalmology 20220708 10


<h4>Background/aims</h4>To investigate the factors associated with choroidal microvasculature drop-out (MvD) enlargement detected by optical coherence tomography angiography (OCT-A) in glaucomatous eyes.<h4>Methods</h4>Ninety-one eyes of 68 primary open-angle glaucoma patients were enrolled. Only eyes with a minimum of four good quality OCT-A and OCT scans of the optic nerve head acquired at least and with a minimum of 2 years follow-up were included. Area and angular circumference of MvD were a  ...[more]

Similar Datasets

| S-EPMC7174329 | biostudies-literature
| S-EPMC8556563 | biostudies-literature
| S-EPMC3410690 | biostudies-literature
| S-EPMC9101256 | biostudies-literature
| S-EPMC5489203 | biostudies-literature
| S-EPMC6298204 | biostudies-literature
| S-EPMC2765944 | biostudies-literature
| S-EPMC7758829 | biostudies-literature
| S-EPMC6547096 | biostudies-literature
| S-EPMC6218041 | biostudies-other