Ontology highlight
ABSTRACT: Objectives
To assess whether instantaneous wave - free ratio (iFR) value is associated with left internal mammary artery (LIMA) graft failure at 12 months follow-up post coronary artery bypass graft (CABG).Background
Data suggests bypass to a non-significant left anterior descending artery (LAD) lesion due to visual over-estimation may lead to LIMA graft failure. Implementing iFR may result in better arterial graft patency.Methods
In iCABG (iFR guided CABG) study patients planned to undergo an isolated CABG procedure was prospectively enrolled and iFR was performed for LAD. Coronary computed tomography angiography was performed at 2 and 12 months follow-up. The primary endpoint of this study was to determine the rate of LIMA graft occlusion or hypoperfusion at 2 and 12-months follow-up. We considered a composite secondary endpoint of Major adverse cardiovascular and cerebrovascular event (MACCE) as a secondary outcome.Results
In total 69 patients were included with no differences regarding age, sex and risk factors. At 2 months, 50 of LIMAs with pre-CABG iFR median 0.855 (0.785 - 0.892) were patent. Hypoperfusion was found in 8 LIMAs (median iFR 0.88 (0.842 - 0.90)). While, 7 LIMAs (median iFR 0.91 (0.88 - 0.96)) were occluded (p = 0.04). At 12 months, when iFR of LAD was >0.85: just 12 (31.6% out of all patent LIMAS) grafts were patent and 24 (100.0% out of all hypoperfused/occluded) grafts were hypoperfused or occluded (p < 0.001). In terms of MACCE, no difference (p = 1.0) was found between all 3 groups divided according to iFR value.Conclusions
Instantaneous wave - free ratio value above 0.85 in LAD is a powerful tool predicting LIMA graft failure at 1-year follow up period.
SUBMITTER: Ordiene R
PROVIDER: S-EPMC10466988 | biostudies-literature | 2023 Sep
REPOSITORIES: biostudies-literature
Ordiene Rasa R Unikas Ramunas R Aldujeli Ali A Benetis Rimantas R Jakuska Povilas P Ceponiene Indre I Jankauskas Antanas A Plisiene Jurgita J Lenkutis Tadas T Rudokaite Gabriele G Braukyliene Rima R Stonis Mindaugas M Davies Justin J Punjabi Prakash P PP
Perfusion 20220506 6
<h4>Objectives</h4>To assess whether instantaneous wave - free ratio (iFR) value is associated with left internal mammary artery (LIMA) graft failure at 12 months follow-up post coronary artery bypass graft (CABG).<h4>Background</h4>Data suggests bypass to a non-significant left anterior descending artery (LAD) lesion due to visual over-estimation may lead to LIMA graft failure. Implementing iFR may result in better arterial graft patency.<h4>Methods</h4>In iCABG (iFR guided CABG) study patients ...[more]