Ontology highlight
ABSTRACT: Background and purpose
Automatic review of breast plan quality for clinical trials is time-consuming and has some unique challenges due to the lack of target contours for some planning techniques. We propose using an auto-contouring model and statistical process control to independently assess planning consistency in retrospective data from a breast radiotherapy clinical trial.Materials and methods
A deep learning auto-contouring model was created and tested quantitatively and qualitatively on 104 post-lumpectomy patients' computed tomography images (nnUNet; train/test: 80/20). The auto-contouring model was then applied to 127 patients enrolled in a clinical trial. Statistical process control was used to assess the consistency of the mean dose to auto-contours between plans and treatment modalities by setting control limits within three standard deviations of the data's mean. Two physicians reviewed plans outside the limits for possible planning inconsistencies.Results
Mean Dice similarity coefficients comparing manual and auto-contours was above 0.7 for breast clinical target volume, supraclavicular and internal mammary nodes. Two radiation oncologists scored 95% of contours as clinically acceptable. The mean dose in the clinical trial plans was more variable for lymph node auto-contours than for breast, with a narrower distribution for volumetric modulated arc therapy than for 3D conformal treatment, requiring distinct control limits. Five plans (5%) were flagged and reviewed by physicians: one required editing, two had clinically acceptable variations in planning, and two had poor auto-contouring.Conclusions
An automated contouring model in a statistical process control framework was appropriate for assessing planning consistency in a breast radiotherapy clinical trial.
SUBMITTER: Baroudi H
PROVIDER: S-EPMC10498301 | biostudies-literature | 2023 Oct
REPOSITORIES: biostudies-literature
Baroudi Hana H Huy Minh Nguyen Callistus I CI Maroongroge Sean S Smith Benjamin D BD Niedzielski Joshua S JS Shaitelman Simona F SF Melancon Adam A Shete Sanjay S Whitaker Thomas J TJ Mitchell Melissa P MP Yvonne Arzu Isidora I Duryea Jack J Hernandez Soleil S El Basha Daniel D Mumme Raymond R Netherton Tucker T Hoffman Karen K Court Laurence L
Physics and imaging in radiation oncology 20230823
<h4>Background and purpose</h4>Automatic review of breast plan quality for clinical trials is time-consuming and has some unique challenges due to the lack of target contours for some planning techniques. We propose using an auto-contouring model and statistical process control to independently assess planning consistency in retrospective data from a breast radiotherapy clinical trial.<h4>Materials and methods</h4>A deep learning auto-contouring model was created and tested quantitatively and qu ...[more]