ABSTRACT: Background
Noise has been reported to occur with relatively high frequency after conventional total knee arthroplasty (C-TKA), and this may impact the incidence of patient satisfaction and function. The purpose of this study was to compare the rate of patient-reported prosthetic noise generation after robotically-assisted TKA (RA-TKA) and C-TKA.Methods
A retrospective study was conducted of unilateral primary RA-TKAs and C-TKAs performed between 2018 and 2021. Patients completed a survey consisting of 4 Likert scale questions related to prosthetic noise generation and Knee Injury and Osteoarthritis Score Joint Replacement and Forgotten Joint Score were assessed prospectively preoperatively and at a minimum of 1-year of clinical follow-up. Statistical analysis was done utilizing T-tests and chi-square tests, with statistical significance defined as a P-value < .05.Results
One hundred sixty-two RA-TKAs and 320 C-TKAs with similar baseline characteristics and functions were included. There were no significant differences in hearing or feeling grinding, popping, clicking, or clunking (40.7% vs 38.1%; P = .647) between groups. Most RA-TKAs and C-TKAs were not dissatisfied regarding noise generation (70.4% vs 73.1%; P = .596). In both cohorts, patients who reported noise generation had lower average Forgotten Joint Scores (45.5 vs 66.1; P < .001) and lower postoperative Knee Injury and Osteoarthritis Score Joint Replacement scores (72.0 vs 81.4; P < .001) than those who did not experience noise generation.Conclusions
While RA-TKA may facilitate soft tissue balancing, there were no differences in prosthetic noise generation between RA-TKA and C-TKA. However, those who experience implant-generated noise have lower functional outcome scores.
SUBMITTER: Cozzarelli NF
PROVIDER: S-EPMC10518686 | biostudies-literature | 2023 Oct
REPOSITORIES: biostudies-literature
Cozzarelli Nicholas F NF Khan Irfan A IA Imam Nareena N Klein Gregg R GR Levine Harlan H Seidenstein Ari A Zaid Musa B MB Lonner Jess H JH
Arthroplasty today 20230916
<h4>Background</h4>Noise has been reported to occur with relatively high frequency after conventional total knee arthroplasty (C-TKA), and this may impact the incidence of patient satisfaction and function. The purpose of this study was to compare the rate of patient-reported prosthetic noise generation after robotically-assisted TKA (RA-TKA) and C-TKA.<h4>Methods</h4>A retrospective study was conducted of unilateral primary RA-TKAs and C-TKAs performed between 2018 and 2021. Patients completed ...[more]