Project description:BackgroundThe anterior-posterior ground reaction force (AP-GRF) and propulsion and braking point metrics derived from the AP-GRF time series are indicators of locomotor function across healthy and neurological diagnostic groups. In this paper, we describe the use of a minimal set of wearable inertial measurement units (IMUs) to indirectly measure the AP-GRFs generated during healthy and hemiparetic walking.MethodsTen healthy individuals and five individuals with chronic post-stroke hemiparesis completed a 6-minute walk test over a walking track instrumented with six forceplates while wearing three IMUs securely attached to the pelvis, thigh, and shank. Subject-specific models driven by IMU-measured thigh and shank angles and an estimate of body acceleration provided by the pelvis IMU were used to generate indirect estimates of the AP-GRF time series. Propulsion and braking point metrics (i.e., peaks, peak timings, and impulses) were extracted from the IMU-generated time series. Peaks and impulses were expressed as % bodyweight (%bw) and peak timing was expressed as % stance phase (%sp). A 75%-25% split of 6-minute walk test data was used to train and validate the models. Indirect estimates of the AP-GRF time series and point metrics were compared to direct measurements made by the forceplates.ResultsIndirect measurements of the AP-GRF time series approximated the direct measurements made by forceplates, with low error and high consistency in both the healthy (RMSE= 4.5%bw; R2= 0.93) and post-stroke (RMSE= 2.64%bw; R2= 0.90) cohorts. In the healthy cohort, the average errors between indirect and direct measurements of the peak propulsion magnitude, peak propulsion timing, and propulsion impulse point estimates were 2.37%bw, 0.67%sp, and 0.43%bw. In the post-stroke cohort, the average errors for these point estimates were 1.07%bw, 1.27%sp, and 0.31%bw. Average errors for the braking estimates were higher, but comparable.ConclusionsAccurate estimates of AP-GRF metrics can be generated using three strategically mounted IMUs and subject-specific calibrations. This study advances the development of point-of-care diagnostic systems that can catalyze the routine assessment and management of propulsion and braking locomotor deficits during rehabilitation.
Project description:A combination of wearable sensors' data and Machine Learning (ML) techniques has been used in many studies to predict specific joint angles and moments. The aim of this study was to compare the performance of four different non-linear regression ML models to estimate lower-limb joints' kinematics, kinetics, and muscle forces using Inertial Measurement Units (IMUs) and electromyographys' (EMGs) data. Seventeen healthy volunteers (9F, 28 ± 5 years) were asked to walk over-ground for a minimum of 16 trials. For each trial, marker trajectories and three force-plates data were recorded to calculate pelvis, hip, knee, and ankle kinematics and kinetics, and muscle forces (the targets), as well as 7 IMUs and 16 EMGs. The features from sensors' data were extracted using the Tsfresh python package and fed into 4 ML models; Convolutional Neural Networks (CNN), Random Forest (RF), Support Vector Machine, and Multivariate Adaptive Regression Spline for targets' prediction. The RF and CNN models outperformed the other ML models by providing lower prediction errors in all intended targets with a lower computational cost. This study suggested that a combination of wearable sensors' data with an RF or a CNN model is a promising tool to overcome the limitations of traditional optical motion capture for 3D gait analysis.
Project description:Our objective was to conduct a scoping review which summarizes the growing body of literature using wearable inertial sensors for gait analysis in lower limb osteoarthritis. We searched six databases using predetermined search terms which highlighted the broad areas of inertial sensors, gait, and osteoarthritis. Two authors independently conducted title and abstract reviews, followed by two authors independently completing full-text screenings. Study quality was also assessed by two independent raters and data were extracted by one reviewer in areas such as study design, osteoarthritis sample, protocols, and inertial sensor outcomes. A total of 72 articles were included, which studied the gait of 2159 adults with osteoarthritis (OA) using inertial sensors. The most common location of OA studied was the knee (n = 46), followed by the hip (n = 22), and the ankle (n = 7). The back (n = 41) and the shank (n = 40) were the most common placements for inertial sensors. The three most prevalent biomechanical outcomes studied were: mean spatiotemporal parameters (n = 45), segment or joint angles (n = 33), and linear acceleration magnitudes (n = 22). Our findings demonstrate exceptional growth in this field in the last 5 years. Nevertheless, there remains a need for more longitudinal study designs, patient-specific models, free-living assessments, and a push for "Code Reuse" to maximize the unique capabilities of these devices and ultimately improve how we diagnose and treat this debilitating disease.
Project description:This work addresses the lack of reliable wearable methods to assess walking gaits in underwater environments by evaluating the lateral hydrodynamic pressure exerted on lower limbs. Sixteen healthy adults were outfitted with waterproof wearable inertial and pressure sensors. Gait analysis was conducted on land in a motion analysis laboratory using an optoelectronic system as reference, and subsequently underwater in a rehabilitation swimming pool. Differences between the normalized land and underwater gaits were evaluated using temporal gait parameters, knee joint angles and the total water pressure on the lower limbs. The proposed method was validated against the optoelectronic system on land; gait events were identified with low bias (0.01s) using Bland-Altman plots for the stride time, and an acceptable error was observed when estimating the knee angle (10.96° RMSE, Bland-Altman bias -2.94°). The kinematic differences between the land and underwater environments were quantified, where it was observed that the temporal parameters increased by more than a factor of two underwater (p<0.001). The subdivision of swing and stance phases remained consistent between land and water trials. A higher variability of the knee angle was observed in water (CV = 60.75%) as compared to land (CV = 31.02%). The intra-subject variability of the hydrodynamic pressure on the foot ([Formula: see text] = 39.65%) was found to be substantially lower than that of the knee angle (CVz = 67.69%). The major finding of this work is that the hydrodynamic pressure on the lower limbs may offer a new and more reliable parameter for underwater motion analysis as it provided a reduced intra-subject variability as compared to conventional gait parameters applied in land-based studies.
Project description:Introduction: Children's walking patterns evolve with age, exhibiting less repetitiveness at a young age and more variability than adults. Three-dimensional gait analysis (3DGA) is crucial for understanding and treating lower limb movement disorders in children, traditionally performed using Optical Motion Capture (OMC). Inertial Measurement Units (IMUs) offer a cost-effective alternative to OMC, although challenges like drift errors persist. Machine learning (ML) models can mitigate these issues in adults, prompting an investigation into their applicability to a heterogeneous pediatric population. This study aimed at 1) quantifying personalized and generalized ML models' performance for predicting gait time series in typically developed (TD) children using IMUs data, 2) Comparing random forest (RF) and convolutional neural networks (CNN) models' performance, 3) Finding the optimal number of IMUs required for accurate predictions. Methodology: Seventeen TD children, aged 6 to 15, participated in data collection involving OMC, force plates, and IMU sensors. Joint kinematics and kinetics (targets) were computed from OMC and force plates' data using OpenSim. Tsfresh, a Python package, extracted features from raw IMU data. Each target's ten most important features were input in the development of personalized and generalized RF and CNN models. This procedure was initially conducted with 7 IMUs placed on all lower limb segments and then performed using only two IMUs on the feet. Results: Findings suggested that the RF and CNN models demonstrated comparable performance. RF predicted joint kinematics with a 9.5% and 19.9% NRMSE for personalized and generalized models, respectively, and joint kinetics with an NRMSE of 10.7% for personalized and 15.2% for generalized models in TD children. Personalized models provided accurate estimations from IMU data in children, while generalized models lacked accuracy due to the limited dataset. Furthermore, reducing the number of IMUs from 7 to 2 did not affect the results, and the performance remained consistent. Discussion: This study proposed a promising personalized approach for gait time series prediction in children, involving an RF model and two IMUs on the feet.
Project description:We propose a co-simulation framework comprising biomechanical human body models and wearable inertial sensor models to analyse gait events dynamically, depending on inertial sensor type, sensor positioning, and processing algorithms. A total of 960 inertial sensors were virtually attached to the lower extremities of a validated biomechanical model and shoe model. Walking of hemiparetic patients was simulated using motion capture data (kinematic simulation). Accelerations and angular velocities were synthesised according to the inertial sensor models. A comprehensive error analysis of detected gait events versus reference gait events of each simulated sensor position across all segments was performed. For gait event detection, we considered 1-, 2-, and 4-phase gait models. Results of hemiparetic patients showed superior gait event estimation performance for a sensor fusion of angular velocity and acceleration data with lower nMAEs (9%) across all sensor positions compared to error estimation with acceleration data only. Depending on algorithm choice and parameterisation, gait event detection performance increased up to 65%. Our results suggest that user personalisation of IMU placement should be pursued as a first priority for gait phase detection, while sensor position variation may be a secondary adaptation target. When comparing rotatory and translatory error components per body segment, larger interquartile ranges of rotatory errors were observed for all phase models i.e., repositioning the sensor around the body segment axis was more harmful than along the limb axis for gait phase detection. The proposed co-simulation framework is suitable for evaluating different sensor modalities, as well as gait event detection algorithms for different gait phase models. The results of our analysis open a new path for utilising biomechanical human digital twins in wearable system design and performance estimation before physical device prototypes are deployed.
Project description:Wearable sensors are becoming increasingly popular for complementing classical clinical assessments of gait deficits. The aim of this review is to examine the existing knowledge by systematically reviewing a large number of papers focusing on the use of wearable inertial sensors for the assessment of gait during the 6-minute walk test (6MWT), a widely recognized, simple, non-invasive, low-cost and reproducible exercise test. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 28 full-text articles. Then, the available knowledge was summarized regarding study design, subjects enrolled (number of patients and pathological condition, if any, age, male/female ratio), sensor characteristics (type, number, sampling frequency, range) and body placement, 6MWT protocol and extracted parameters. Results were critically discussed to suggest future directions for the use of inertial sensor devices in the clinics.
Project description:Real-world gait analysis can aid in clinical assessments and influence related interventions, free from the restrictions of a laboratory setting. Using individual accelerometers, we aimed to use a simple machine learning method to quantify the performance of the discrimination between three self-selected cyclical locomotion types using accelerometers placed at frequently referenced attachment locations. Thirty-five participants walked along a 10 m walkway at three different speeds. Triaxial accelerometers were attached to the sacrum, thighs and shanks. Slabs of magnitude, three-second-long accelerometer data were transformed into two-dimensional Fourier spectra. Principal component analysis was undertaken for data reduction and feature selection, followed by discriminant function analysis for classification. Accuracy was quantified by calculating scalar accounting for the distances between the three centroids and the scatter of each category's cloud. The algorithm could successfully discriminate between gait modalities with 91% accuracy at the sacrum, 90% at the shanks and 87% at the thighs. Modalities were discriminated with high accuracy in all three sensor locations, where the most accurate location was the sacrum. Future research will focus on optimising the data processing of information from sensor locations that are advantageous for practical reasons, e.g., shank for prosthetic and orthotic devices.
Project description:In this paper, we develop an algorithm to automatically validate and segment a gait cycle in real time into three gait events, namely midstance, toe-off, and heel-strike, using inertial sensors. We first use the physical models of sensor data obtained from a foot-mounted inertial system to differentiate stationary and moving segments of the sensor data. Next, we develop an optimization routine called sparsity-assisted wavelet denoising (SAWD), which simultaneously combines linear time invariant filters, orthogonal multiresolution representations such as wavelets, and sparsity-based methods, to generate a sparse template of the moving segments of the gyroscope measurements in the sagittal plane for valid gait cycles. Thereafter, to validate any moving segment as a gait cycle, we compute the root-mean-square error between the generated sparse template and the sparse representation of the moving segment of the gyroscope data in the sagittal plane obtained using SAWD. Finally, we find the local minima for the stationary and moving segments of a valid gait cycle to detect the gait events. We compare our proposed method with existing methods, for a fixed threshold, using real data obtained from three groups, namely controls, participants with Parkinson disease, and geriatric participants. Our proposed method demonstrates an average F1 score of 87.78% across all groups for a fixed sampling rate, and an average F1 score of 92.44% across all Parkinson disease participants for a variable sampling rate.
Project description:The increased variations of temporal gait events when pathology is present are good candidate features for objective diagnostic tests. We hypothesised that the gait events hoof-on/off and stance can be detected accurately and precisely using features from trunk and distal limb-mounted Inertial Measurement Units (IMUs). Four IMUs were mounted on the distal limb and five IMUs were attached to the skin over the dorsal spinous processes at the withers, fourth lumbar vertebrae and sacrum as well as left and right tuber coxae. IMU data were synchronised to a force plate array and a motion capture system. Accuracy (bias) and precision (SD of bias) was calculated to compare force plate and IMU timings for gait events. Data were collected from seven horses. One hundred and twenty three (123) front limb steps were analysed; hoof-on was detected with a bias (SD) of -7 (23) ms, hoof-off with 0.7 (37) ms and front limb stance with -0.02 (37) ms. A total of 119 hind limb steps were analysed; hoof-on was found with a bias (SD) of -4 (25) ms, hoof-off with 6 (21) ms and hind limb stance with 0.2 (28) ms. IMUs mounted on the distal limbs and sacrum can detect gait events accurately and precisely.