Project description:Radiobiology research in rectal cancer has been limited to cell lines, patient-derived organoids (PDOs), or xenografts. Here, we describe a protocol which recapitulates more efficiently the complex contributions of the tumor microenvironment. This approach establishes a preclinical mouse model of rectal cancer by intrarectal transplantation of genetically modified organoids into immunocompetent mice followed by precise image-guided radiotherapy (IGRT) of organoid-induced tumors. This model represents a useful platform to study the cellular and molecular determinants of therapy resistance in rectal cancer. For complete details on the use and execution of this protocol, please refer to Nicolas et al. (2022).
Project description:BackgroundWe report the results of a retrospective analysis of localized prostate cancer (LPCa) treated with transperineal ultrasound image-guided radiotherapy (TPUS-IGRT).MethodsA total of 124 patients (median age: 74 y, 46-84 y) with LPCa who underwent TPUS-IGRT (Clarity Autoscan system; CAS, Elekta; Stockholm, Sweden) between April 2016 and October 2021 for curative/after hormone induction were enrolled. The number of patients by risk (National Comprehensive Cancer Network 2019) was 7, 25, 42, and 50 for low (LR), good intermediate (good IR), poor intermediate (poor IR), and high (HR)/very high (VHR), respectively. Ninety-five patients were given neoadjuvant hormonal therapy. The planning target volume margin setting was 3 mm for rectal in most cases, 5-7 mm for superior/inferior, and 5 mm for anterior/right/left. The principle prescribed dose is 74 Gy (LR), 76 Gy (good IR), and 76-78 Gy (poor IR or above). CAS was equipped with a real-time prostate intrafraction monitoring (RTPIFM) system. When a displacement of 2-3 mm or more was detected, irradiation was paused, and the patients were placed on standby for prostate reinstatement/recorrection. Of the 3135 fractions in 85 patients for whom RTPIFM was performed, 1008 fractions (32.1%) were recorrected at least once after starting irradiation.ResultsA total of 123 patients completed the radiotherapy course. The 5-year overall survival rate was 95.9%. The 5-year biological prostate-specific antigen relapse-free survival rate (bPFS) was 100% for LR, 92.9% for intermediate IR, and 93.2% for HR/VHR (Phoenix method). The 5-year late toxicity rate of Grade 2+ was 7.4% for genitourinary (GU) and 6.5% for gastrointestinal (GI) organs. Comparing the ≤ 76 Gy group to the 78 Gy group for both GU and GI organs, the incidence was higher in the 78 Gy group for both groups.ConclusionThese results suggest that TPUS-IGRT is well tolerated, as the bPFS and incidence of late toxicity are almost comparable to those reported by other sources of image-guided radiotherapy.
Project description:When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose-response relationships. We investigated this for rectal bleeding using dose-volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman-Kutcher-Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose-response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice thickness variations within this range.
Project description:BackgroundGastro-intestinal (GI) toxicity after radiotherapy (RT) for prostate cancer reduces patient's quality of life. In this study, we explored associations between spatial rectal dose/volume metrics and patient-reported GI symptoms after RT for localized prostate cancer, and compared these with those of dose-surface/volume histogram (DSH/DVH) metrics.Material and methodsDose distributions and six GI symptoms (defecation urgency/emptying difficulties/fecal leakage, ≥Grade 2, median follow-up: 3.6 y) were extracted for 200 patients treated with image-guided RT in 2005-2007. Three hundred and nine metrics assessed from 2D rectal dose maps or DSHs/DVHs were subject to 50-times iterated five-fold cross-validated univariate and multivariate logistic regression analysis (UVA, MVA). Performance of the most frequently selected MVA models was evaluated by the area under the receiving-operating characteristics curve (AUC).ResultsThe AUC increased for dose-map compared to DSH/DVH-based models (mean SD: 0.64 ± 0.03 vs. 0.61 ± 0.01), and significant relations were found for six versus four symptoms. Defecation urgency and faecal leakage were explained by high doses at the central/upper and central areas, respectively; while emptying difficulties were explained by longitudinal extensions of intermediate doses.ConclusionsPredictability of patient-reported GI toxicity increased using spatial metrics compared to DSH/DVH metrics. Novel associations were particularly identified for emptying difficulties using both approaches in which intermediate doses were emphasized.
Project description:PurposeTo evaluate deep learning (DL)-based deformable image registration (DIR) for dose accumulation during radiotherapy of prostate cancer patients.Methods and materialsData including 341 CBCTs (209 daily, 132 weekly) and 23 planning CTs from 23 patients was retrospectively analyzed. Anatomical deformation during treatment was estimated using free-form deformation (FFD) method from Elastix and DL-based VoxelMorph approaches. The VoxelMorph method was investigated using anatomical scans (VMorph_Sc) or label images (VMorph_Msk), or the combination of both (VMorph_Sc_Msk). Accumulated doses were compared with the planning dose.ResultsThe DSC ranges, averaged for prostate, rectum and bladder, were 0.60-0.71, 0.67-0.79, 0.93-0.98, and 0.89-0.96 for the FFD, VMorph_Sc, VMorph_Msk, and VMorph_Sc_Msk methods, respectively. When including both anatomical and label images, VoxelMorph estimated more complex deformations resulting in heterogeneous determinant of Jacobian and higher percentage of deformation vector field (DVF) folding (up to a mean value of 1.90% in the prostate). Large differences were observed between DL-based methods regarding estimation of the accumulated dose, showing systematic overdosage and underdosage of the bladder and rectum, respectively. The difference between planned mean dose and accumulated mean dose with VMorph_Sc_Msk reached a median value of +6.3 Gy for the bladder and -5.1 Gy for the rectum.ConclusionThe estimation of the deformations using DL-based approach is feasible for male pelvic anatomy but requires the inclusion of anatomical contours to improve organ correspondence. High variability in the estimation of the accumulated dose depending on the deformable strategy suggests further investigation of DL-based techniques before clinical deployment.
Project description:Despite the use of clinical prognostic factors (PSA, T-category and Gleason score), 20-60% of localized prostate cancers (PCa) fail primary local treatment. Herein, we determined the prognostic importance of main sensors of the DNA damage response (DDR): MRE11A, RAD50, NBN, ATM, ATR and PRKDC. We studied copy number alterations in DDR genes in localized PCa treated with image-guided radiotherapy (IGRT; n=139) versus radical prostatectomy (RadP; n=154). In both cohorts, NBN gains were the most frequent genomic alteration (14.4 and 11% of cases, respectively), and were associated with overall tumour genomic instability (p<0.0001). NBN gains were the only significant predictor of 5yrs biochemical relapse-free rate (bRFR) following IGRT (46% versus 77%; p=0.00067). On multivariate analysis, NBN gain remained a significant independent predictor of bRFR after adjusting for known clinical prognostic variables (HR=3.28, 95% CI 1.56-6.89, Wald p-value=0.0017). No DDR-sensing gene was prognostic in the RadP cohort. In vitro studies correlated NBN gene overexpression with PCa cells radioresistance. In conclusion, NBN gain predicts for decreased bRFR in IGRT, but not in RadP patients. If validated independently, Nibrin gains may be the first PCa predictive biomarker to facilitate local treatment decisions using precision medicine approaches with surgery or radiotherapy.
Project description:BackgroundImage-guided radiotherapy (IGRT) has gradually been widely promoted in clinical procedure. However, there has been no consensus on the effects of IGRT on toxicity and survival, and no clear level 1 evidence has even been promulgated.MethodsMedline, EMBASE, PubMed, Cochrane databases and ClinicalTrials.gov were searched for studies comparing IGRT vs non-IGRT or higher frequency IGRT vs lower frequency IGRT during prostate radiotherapy, indexed from database inception to April 2022.ResultsThe review included 18 studies (3 randomized clinical trial and 15 cohort studies) involving 6521 men, with a median duration of patient follow-up of 46.2 months in the IGRT group vs 52.7 months in the control group. The meta-analysis demonstrated that IGRT significantly reduced acute GU (risk ratio [RR], 0.78; 95 % confidence interval [CI], 0.69-0.88; P < 0.001 [9 studies]) and GI toxicity (RR, 0.49; 95 % CI, 0.35-0.68; P < 0.001 [4 studies]) and late GI toxicity (HR, 0.25; 95 % CI, 0.07-0.87; P = 0.03 [3 studies]) compared with non-IGRT. Meanwhile, compared with prospective studies, retrospective studies showed that IGRT had a more significant effect in reducing the late GI toxicity. Compared with non-daily IGRT, daily IGRT significantly improved 3-year PRFS (HR, 0.45; 95 % CI, 0.28-0.72; P = 0.001 [2 studies]) and BFFS (HR, 0.57; 95 % CI, 0.39-0.83; P = 0.003 [3 studies]). Furthermore, high-frequency daily IGRT could lead to greater 3-year BFFS benefit in prostate cancer patients than weekly IGRT. However, no significant effects of IGRT on acute rectal toxicity, late GU toxicity, 5-year OS and SCM were found.ConclusionsFor men receiving prostate radiotherapy, IGRT was associated with an improvement in biochemical tumor control and a reduction in GI and acute GU toxicity, but did not significantly improve 5-year OS or increase 5-year SCM.
Project description:External beam radiotherapy remains the primary treatment modality for localized prostate cancer. The radiobiology of prostate carcinoma lends itself to hypofractionation, with recent studies showing good outcomes with shorter treatment schedules. However, the ability to accurately deliver hypofractionated treatment is limited by current image-guided techniques. Magnetic resonance imaging is the main diagnostic tool for localized prostate cancer and its use in the therapeutic setting offers anatomical information to improve organ delineation. MR-guided radiotherapy, with daily re-planning, has shown early promise in the accurate delivery of radiotherapy. In this article, we discuss the shortcomings of current image-guidance strategies and the potential benefits and limitations of MR-guided treatment for prostate cancer. We also recount present experiences of MR-linac workflow and the opportunities afforded by this technology.