One-step rolling fabrication of VO2 tubular bolometers with polarization-sensitive and omnidirectional detection.


ABSTRACT: Uncooled infrared detection based on vanadium dioxide (VO2) radiometer is highly demanded in temperature monitoring and security protection. The key to its breakthrough is to fabricate bolometer arrays with great absorbance and excellent thermal insulation using a straightforward procedure. Here, we show a tubular bolometer by one-step rolling VO2 nanomembranes with enhanced infrared detection. The tubular geometry enhances the thermal insulation, light absorption, and temperature sensitivity of freestanding VO2 nanomembranes. This tubular VO2 bolometer exhibits a detectivity of ~2 × 108 cm Hz1/2 W-1 in the ultrabroad infrared spectrum, a response time of ~2.0 ms, and a calculated noise-equivalent temperature difference of 64.5 mK. Furthermore, our device presents a workable structural paradigm for polarization-sensitive and omnidirectional light coupling bolometers. The demonstrated overall characteristics suggest that tubular bolometers have the potential to narrow performance and cost gap between photon detectors and thermal detectors with low cost and broad applications.

SUBMITTER: Wu B 

PROVIDER: S-EPMC10584336 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

One-step rolling fabrication of VO<sub>2</sub> tubular bolometers with polarization-sensitive and omnidirectional detection.

Wu Binmin B   Zhang Ziyu Z   Chen Bingxin B   Zheng Zhi Z   You Chunyu C   Liu Chang C   Li Xing X   Wang Jinlong J   Wang Yunqi Y   Song Enming E   Cui Jizhai J   An Zhenghua Z   Huang Gaoshan G   Mei Yongfeng Y  

Science advances 20231018 42


Uncooled infrared detection based on vanadium dioxide (VO<sub>2</sub>) radiometer is highly demanded in temperature monitoring and security protection. The key to its breakthrough is to fabricate bolometer arrays with great absorbance and excellent thermal insulation using a straightforward procedure. Here, we show a tubular bolometer by one-step rolling VO<sub>2</sub> nanomembranes with enhanced infrared detection. The tubular geometry enhances the thermal insulation, light absorption, and temp  ...[more]

Similar Datasets

| S-EPMC9742311 | biostudies-literature
| S-EPMC8566179 | biostudies-literature
| S-EPMC10268973 | biostudies-literature
| S-EPMC7933432 | biostudies-literature
| S-EPMC7297976 | biostudies-literature
| S-EPMC11787348 | biostudies-literature
| S-EPMC9165497 | biostudies-literature
| S-EPMC8779663 | biostudies-literature
| S-EPMC11416676 | biostudies-literature
| S-EPMC11412996 | biostudies-literature