Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression.


ABSTRACT:

Background

Pulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia.

Methods

Systematic review and metanalysis of PPV and SVV use in surgical adult patients. The QUADAS-2 scale was used to assess the risk of bias of included studies. We adopted a metanalysis pooling of aggregate data from 5 subgroups of studies with random effects models using the common-effect inverse variance model. The area under the curve (AUC) of pooled receiving operating characteristics (ROC) curves was reported. A metaregression was performed using FC type, volume, and rate as independent variables.

Results

We selected 59 studies enrolling 2,947 patients, with a median of fluid responders of 55% (46-63). The pooled AUC for the PPV was 0.77 (0.73-0.80), with a mean threshold of 10.8 (10.6-11.0). The pooled AUC for the SVV was 0.76 (0.72-0.80), with a mean threshold of 12.1 (11.6-12.7); 19 studies (32.2%) reported the grey zone of PPV or SVV, with a median of 56% (40-62) and 57% (46-83) of patients included, respectively. In the different subgroups, the AUC and the best thresholds ranged from 0.69 and 0.81 and from 6.9 to 11.5% for the PPV, and from 0.73 to 0.79 and 9.9 to 10.8% for the SVV. A high Vt and the choice of colloids positively impacted on PPV performance, especially among patients with closed chest and abdomen, or in prone position.

Conclusion

The overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.

Trial registration

PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120.

SUBMITTER: Messina A 

PROVIDER: S-EPMC10631038 | biostudies-literature | 2023 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression.

Messina Antonio A   Caporale Mariagiovanna M   Calabrò Lorenzo L   Lionetti Giulia G   Bono Daniele D   Matronola Guia Margherita GM   Brunati Andrea A   Frassanito Luciano L   Morenghi Emanuela E   Antonelli Massimo M   Chew Michelle S MS   Cecconi Maurizio M  

Critical care (London, England) 20231108 1


<h4>Background</h4>Pulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia.<h4>Methods</h4>Systematic review and metanalysis of P  ...[more]

Similar Datasets

| S-EPMC6664788 | biostudies-literature
| 2675566 | ecrin-mdr-crc
| S-EPMC4595532 | biostudies-literature
| PRJEB11484 | ENA
| S-EPMC5512836 | biostudies-literature
| S-EPMC8190124 | biostudies-literature
| S-EPMC8193042 | biostudies-literature
| S-EPMC6984427 | biostudies-literature
| S-EPMC9584484 | biostudies-literature
| S-EPMC6694235 | biostudies-literature