Project description:Valve-in-mitral annular calcification presents a great challenge with a risk of left ventricular outflow tract obstruction (LVOTO). We demonstrate the first-in-human experience of performing percutaneous electrosurgery-guided perforation and balloon dilation of the anterior mitral valve leaflet followed by transcatheter valve implantation to prevent LVOTO.
Project description:Transcatheter closure of mitral valve leaflet perforation is a very rarely performed and a difficult procedure for repairing the defect. Herein, we are the first to report on both the safety and feasibility of percutaneous retrograde transcatheter closure of anterior mitral valve leaflet perforation with an AMPLATZER™ Duct Occluder II (6 mm × 6 mm, ADO II; Abbott Vascular, IL, USA) device in a 19-year-old patient with a severe mitral valve regurgitation following cardiac surgery.
Project description:ObjectivesThe systolic anterior motion (SAM) of mitral valves occurs at a certain rate despite the introduction of several preventive procedures. The purpose of this study was to investigate its mechanism by analysing the change in mitral valve morphology associated with operative procedures.MethodsComponents of mitral valves were measured before and after operative procedures by transoesophageal echocardiography in 179 patients who underwent mitral valve repair. Comparisons were made between 15 patients with SAM (SAM group) and 164 patients without SAM (non-SAM group).ResultsMorphological analysis in all the studied patients revealed that operative procedures shifted the coaptation point towards the left ventricular outflow tract by 6.9 mm and increased the extra portion of anterior leaflet that extended beyond the coaptation point by 5.4 mm. These changes were enhanced in the SAM group. Intergroup comparison revealed that there were no differences in the preoperative mitral valve morphologies between the two groups. After operative procedures, however, the SAM group showed smaller annular diameter and smaller coapted anterior/posterior length ratio compared with the non-SAM group.ConclusionsThe results of this study show that operative procedures might modify the morphology of mitral valves susceptible to developing SAM. Postoperative smaller annular diameter and anterior shift of coaptation point were considered to contribute to the development of SAM.
Project description:ObjectivesThe aim of this study was to test the hypothesis that transcatheter electrosurgery might allow intentional detachment of previously placed MitraClip(s) from the anterior leaflet to recreate a single mitral orifice for transcatheter mitral valve implantation (TMVI), leaving the retained MitraClip(s) securely fastened to the posterior leaflet and without interfering with the mitral bioprosthesis.BackgroundPatients with severe mitral regurgitation or stenosis despite edge-to-edge mitral repair with the MitraClip typically have few therapeutic options because the resultant double orifice precludes TMVI. Transcatheter electrosurgery may allow detachment of failed MitraClip(s) from the anterior leaflet to recreate a single orifice for TMVI.MethodsThis was a single-center, 5-patient, consecutive, retrospective observational cohort. Patients underwent transcatheter electrosurgical laceration and stabilization of failed MitraClip(s) to recreate a single orifice, leaving the MitraClip(s) securely fastened to the posterior leaflet. Subsequently, patients underwent TMVI with an investigational device, the Tendyne mitral bioprosthesis, on a compassionate basis. Patients were followed up to 30 days.ResultsMitraClip detachment from the anterior leaflet and Tendyne implantation were successful in all patients. All patients survived to discharge. All patients were discharged with grade 0 central mitral regurgitation. Two patients had moderate perivalvular mitral regurgitation that did not require reintervention. During the follow-up period of 30 days, there were no deaths, cases of valve dysfunction, or reintervention. There was no evidence of erosion or bioprosthetic valve dysfunction attributable to the retained MitraClip(s) still attached to the posterior leaflet.ConclusionsTranscatheter electrosurgical detachment of failed MitraClips from the anterior leaflet followed by TMVI is technically feasible and safe at 30 days. Longer term study is needed to determine the clinical benefit of this approach and new algorithms for TMVI sizing following electrosurgical laceration and stabilization of a failed MitraClip to avoid perivalvular leak.
Project description:A patient with myxomatous mitral valve prolapse underwent mitral mitral valve repair due to severe symptomatic mitral regurgitation. Preoperative echocardiography demonstrated systolic anterior motion of the mitral valve. This finding disappeared once spontaneous chordal rupture occurred, resulting in a flail posterior mitral leaflet. As the patient was considered at high risk of developing post-repair SAM, he was operated on using surgical techniques aimed at lowering the risk of this complication. Despite this, post-repair SAM did develop and could only be eliminated by a surgical edge-to-edge (Alfieri) repair.
Project description:BackgroundLeft ventricular outflow tract (LVOT) obstruction is a leading cause of mortality and exclusion from transcatheter mitral valve replacement (TMVR). Intentional laceration of the anterior mitral valve leaflet to prevent LVOT obstruction (LAMPOON) is a transcatheter mimic of surgical chord-sparing leaflet resection.ObjectivesThe purpose of this prospective multicenter trial was to study LAMPOON with transseptal (Edwards Lifesciences, Irvine, California) TMVR in annuloplasty rings or native mitral annular calcification (MAC).MethodsSubjects at high or extreme surgical risk and prohibitive risk of LVOT obstruction from TMVR were included. Eligibility was modified midtrial to exclude subjects with threatened LVOT obstruction from a Sapien 3 valve fabric skirt. The primary endpoint was procedure survival with successful LAMPOON, with successful TMVR, without reintervention, and with LVOT gradient <30 mm Hg ("optimal") or <50 mm Hg ("acceptable"). Secondary endpoints included 30-day mortality and major adverse cardiovascular events. There was universal source-data verification and independent monitoring. All endpoints were independently adjudicated. Central laboratories analyzed echocardiogram and CT images.ResultsBetween June 2017 and June 2018, 30 subjects were enrolled equally between the MAC and ring arms. LAMPOON traversal and midline laceration was successful in 100%. Procedure survival was 100%, and 30-day survival was 93%. Primary success was achieved in 73%, driven by additional procedures for paravalvular leak (10%) and high-skirt neo-LVOT gradients observed before a protocol amendment. There were no strokes.ConclusionsLAMPOON was feasible in native and annuloplasty ring anatomies in patients who were otherwise ineligible for treatment, with acceptable safety. LAMPOON was effective in preventing LVOT obstruction from TMVR. Despite LAMPOON, TMVR using Sapien 3 in annuloplasty rings and MAC still exhibits important limitations. (NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation; NCT03015194).
Project description:Background and objectiveThe prevalence of hypertrophic cardiomyopathy (HCM) is estimated to be 1 in 200 to 500 individuals, with systolic anterior motion (SAM) of the mitral valve (MV) and left ventricular outflow tract (LVOT) obstruction present in 60% to 70%. In this narrative review, we aim to elucidate the pathophysiology of SAM-septal contact and LVOT obstruction in HCM by presenting a detailed review on the anatomy of the MV apparatus in HCM, examining the various existing theories pertaining to the SAM phenomenon as supported by cardiac imaging, and providing a critical assessment of management strategies for SAM in HCM.MethodsA literature review was performed using PubMed, EMBASE, Ovid, and the Cochrane Library, of all scientific articles published through December 2021. A focus was placed on descriptive studies, reports correlating echocardiographic findings with pathologic diagnosis, and outcomes studies.Key content and findingsThe pathophysiology of SAM involves the complex interplay between HCM morphology, MV apparatus anatomic abnormalities, and labile hemodynamic derangements. Echocardiography and cardiac magnetic resonance (CMR) vector flow mapping have identified drag forces, as opposed to the "Venturi effect", as the main hydraulic forces responsible for SAM. The degree of mitral regurgitation with SAM is variable, and its severity is correlated with degree of LVOT obstruction and outcomes. First line therapy for the amelioration of SAM and LVOT obstruction is medical therapy with beta-blockers, non-dihydropyridine calcium-channel blockers, and disopyramide, in conjunction with lifestyle modifications. In refractory cases septal reduction therapy is performed, which may be combined with a 'resect-plicate-release' procedure, anterior mitral leaflet extension, surgical edge-to-edge MV repair, anterior mitral leaflet retention plasty, or secondary chordal cutting.ConclusionsRecent scientific advances in the field of HCM have allowed for a maturation of our understanding of the SAM phenomenon. Cardiac imaging plays a critical role in its diagnosis, treatment, and surveillance, and in our ability to apply the appropriate therapeutic regimens. The increasing prevalence of HCM places an emphasis on continued basic and clinical research to further improve outcomes for this challenging population.