Unknown

Dataset Information

0

Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting.


ABSTRACT: The National Institute of Cardiology has previously used the CoaguChek® XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliability of PT/INR results using the third-generation CoaguChek Pro II system, the CoaguChek XS Plus system, and cobas® t 411 for citrated plasma analysis. Venous and capillary PT/INR were measured (N = 204). Spearman's correlation, Bland-Altman, and concordance analysis between methods were conducted. Spearman's correlation coefficients between venous/capillary INR were high for CoaguChek Pro II versus CoaguChek XS Plus (r = 0.994), CoaguChek Pro II versus cobas t 411 (r = 0.967), and CoaguChek XS Plus versus cobas t 411 (r = 0.968). Good concordance was observed among capillary methods (concordance coefficient [κ] = 0.888) and remaining relationships (P < .001 for all): cobas t 411 versus CoaguChek XS Plus (κ = 0.696) and cobas t 411 versus CoaguChek Pro II (κ = 0.684). In conclusion, good agreement was observed between CoaguChek Pro II, CoaguChek XS Plus, and cobas t 411.

SUBMITTER: Cortina-de-la-Rosa E 

PROVIDER: S-EPMC10686019 | biostudies-literature | 2023 Jan-Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting.

Cortina-de-la-Rosa Evelyn E   Izaguirre-Ávila Raúl R   Ramírez-Hernández Alejandro A   Romero-Arroyo María-Oliva MO   Cortés-Cortés Karen K  

Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis 20230101


The National Institute of Cardiology has previously used the CoaguChek<sup>®</sup> XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliability of PT/INR results using the third-generation CoaguChek Pro II system, the CoaguChek XS Plus system, and cobas<sup>®</sup> t 411 for citrated plasma analysis. Venous and capillary PT/INR wer  ...[more]

Similar Datasets

| S-EPMC10229219 | biostudies-literature
| S-EPMC9435534 | biostudies-literature
| S-EPMC6205738 | biostudies-literature
| S-EPMC11301202 | biostudies-literature
| S-EPMC2851552 | biostudies-other
| S-EPMC9584709 | biostudies-literature
| S-EPMC8464464 | biostudies-literature
| S-EPMC9612453 | biostudies-literature
| S-EPMC7745188 | biostudies-literature
| S-EPMC9775588 | biostudies-literature