Respiratory monitoring dataset, with rapid expiratory occlusions, over increasing positive airway pressure ventilation.


ABSTRACT: Resting breathing data was collected from 80 smokers, vapers, asthmatics, and otherwise healthy people in the low-risk clinical unit at the University of Canterbury. Subjects were asked to breathe normally through a full-face mask connected to a Fisher and Paykel Healthcare SleepStyle SPSCAA CPAP device. PEEP (Positive End-Expiratory Pressure) support was increased from 4 to 12 cmH2O in 0.5 cmH2O increments. Data was also collected during resting breathing at ZEEP (0 cmH2O) before and after the PEEP trial. The trial was conducted under University of Canterbury Human Research Ethics Committee consent (Ref: HREC 2023/04/LR-PS). Data was collected by and Dräeger PulmoVista 500 EIT machine and a custom Venturi-based pressure and flow sensor device connected in series with the CPAP and full-face mask. The outlined dataset includes pressure, flow, volume, dynamic circumference (thoracic and abdominal, and cross-sectional aeration. Subject demographic data was self-reported using a questionnaire given prior to the trial.

SUBMITTER: Guy EFS 

PROVIDER: S-EPMC10749260 | biostudies-literature | 2024 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Respiratory monitoring dataset, with rapid expiratory occlusions, over increasing positive airway pressure ventilation.

Guy Ella F S EFS   Clifton Jaimey A JA   Calje-Van Der Klei Trudy T   Chen Rongqing R   Knopp Jennifer L JL   Möller Knut K   Chase J Geoffrey JG  

Data in brief 20231201


Resting breathing data was collected from 80 smokers, vapers, asthmatics, and otherwise healthy people in the low-risk clinical unit at the University of Canterbury. Subjects were asked to breathe normally through a full-face mask connected to a Fisher and Paykel Healthcare SleepStyle SPSCAA CPAP device. PEEP (Positive End-Expiratory Pressure) support was increased from 4 to 12 cmH<sub>2</sub>O in 0.5 cmH<sub>2</sub>O increments. Data was also collected during resting breathing at ZEEP (0 cmH<su  ...[more]

Similar Datasets

| S-EPMC10754699 | biostudies-literature
| S-EPMC11786409 | biostudies-literature
| S-EPMC7385937 | biostudies-literature
| S-EPMC3177558 | biostudies-literature
| S-EPMC4990945 | biostudies-literature
2023-04-12 | GSE228739 | GEO
| S-EPMC2887141 | biostudies-literature
| S-EPMC7439797 | biostudies-literature
| S-EPMC7808079 | biostudies-literature
| S-EPMC9104897 | biostudies-literature