Project description:ObjectivesTo investigate the proportion of lateral flow tests (LFTs) that produce negative results in those with a high risk of infectiousness from SARS-CoV-2, to investigate the impact of the stage and severity of disease, and to compare predictions made by influential mathematical models with findings of empirical studies.DesignLinked data analysis combining empirical evidence of the accuracy of the Innova LFT, the probability of positive viral culture or transmission to secondary cases, and the distribution of viral loads of SARS-CoV-2 in individuals in different settings.SettingTesting of individuals with symptoms attending NHS Test-and-Trace centres across the UK, residents without symptoms attending municipal mass testing centres in Liverpool, and students without symptoms screened at the University of Birmingham.ParticipantsEvidence for the sensitivity of the Innova LFT, based on 70 individuals with SARS-CoV-2 and LFT results. Infectiousness was based on viral culture rates on 246 samples (176 people with SARS-CoV-2) and secondary cases among 2 474 066 contacts; distributions of cycle threshold (Ct) values from 231 497 index individuals attending NHS Test-and-Trace centres; 70 people with SARS-CoV-2 detected in Liverpool and 62 people with SARS-CoV-2 in Birmingham (54 imputed).Main outcome measuresThe predicted proportions who were missed by LFT and viral culture positive and missed by LFT and sources of secondary cases, in each of the three settings. Predictions were compared with those made by mathematical models.ResultsThe analysis predicted that of those with a viral culture positive result, Innova would miss 20% attending an NHS Test-and-Trace centre, 29% without symptoms attending municipal mass testing, and 81% attending university screen testing without symptoms, along with 38%, 47%, and 90% of sources of secondary cases. In comparison, two mathematical models underestimated the numbers of missed infectious individuals (8%, 10%, and 32% in the three settings for one model, whereas the assumptions from the second model made it impossible to miss an infectious individual). Owing to the paucity of usable data, the inputs to the analyses are from limited sources.ConclusionsThe proportion of infectious people with SARS-CoV-2 missed by LFTs is substantial enough to be of clinical importance. The proportion missed varied between settings because of different viral load distributions and is likely to be highest in those without symptoms. Key models have substantially overestimated the sensitivity of LFTs compared with empirical data. An urgent need exists for additional robust well designed and reported empirical studies from intended use settings to inform evidence based policy.
Project description:Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine coverage remains incomplete, being only 15% in low-income countries. Rapid point-of-care tests predicting SARS-CoV-2 infection susceptibility in the unvaccinated may assist in risk management and vaccine prioritization. We conducted a prospective cohort study in 2,826 participants working in hospitals and Fire and Police services in England, UK, during the pandemic (ISRCTN5660922). Plasma taken at recruitment in June 2020 was tested using four lateral flow immunoassay (LFIA) devices and two laboratory immunoassays detecting antibodies against SARS-CoV-2 (UK Rapid Test Consortium's AbC-19 rapid test, OrientGene COVID IgG/IgM rapid test cassette, SureScreen COVID-19 rapid test cassette, and Biomerica COVID-19 IgG/IgM rapid test; Roche N and Euroimmun S laboratory assays). We monitored participants for microbiologically confirmed SARS-CoV-2 infection for 200 days. We estimated associations between test results at baseline and subsequent infection, using Poisson regression models adjusted for baseline demographic risk factors for SARS-CoV-2 exposure. Positive IgG results on each of the four LFIAs were associated with lower rates of subsequent infection with adjusted incidence rate ratios (aIRRs) of 0.00 (95% confidence interval, 0.00 to 0.01), 0.03 (0.02 to 0.05), 0.07 (0.05 to 0.10), and 0.09 (0.07 to 0.12), respectively. The protective association was strongest for AbC-19 and SureScreen. The aIRR for the laboratory Roche N antibody assay at the manufacturer-recommended threshold was similar to those of the two best performing LFIAs at 0.03 (0.01 to 0.10). Lateral flow devices measuring SARS-CoV-2 IgG predicted disease risk in unvaccinated individuals over a 200-day follow-up. The association of some LFIAs with subsequent infection was similar to laboratory immunoassays. IMPORTANCE Previous research has demonstrated an association between the detection of antibodies to SARS-CoV-2 following natural infection and protection from subsequent symptomatic SARS-CoV-2 infection. Lateral flow immunoassays (LFIAs) detecting anti-SARS-CoV-2 IgG are a cheap, readily deployed technology that has been used on a large scale in population screening programs, yet no studies have investigated whether LFIA results are associated with subsequent SARS-CoV-2 infection. In a prospective cohort study of 2,826 United Kingdom key workers, we found positivity in lateral flow test results had a strong negative association with subsequent SARS-CoV-2 infection within 200 days in an unvaccinated population. Positivity on more-specific but less-sensitive tests was associated with a markedly decreased rate of disease; protection associated with testing positive using more sensitive devices detecting lower levels of anti-SARS-CoV-2 IgG was more modest. Lateral flow tests with high specificity may have a role in estimation of SARS-CoV-2 disease risk in unvaccinated populations.
Project description:ObjectiveTo define the relationship of SARS-CoV-2 antigen, viral load determined by RT-qPCR, and viral culture detection. Presumptively, viral culture can provide a surrogate measure for infectivity of sampled individuals and thereby inform how and where to most appropriately deploy antigen and nucleic acid amplification-based diagnostic testing modalities.MethodsWe compared the antigen testing results from three lateral flow and one microfluidics assay to viral culture detection and viral load determination performed in parallel in up to 189 nasopharyngeal swab samples positive for SARS-CoV-2. Sample viral loads, determined by RT-qPCR, were distributed across the range of viral load values observed in our testing population.ResultsAntigen tests were predictive of viral culture positivity, with the LumiraDx microfluidics method showing enhanced sensitivity (90%; 95% CI 83-94%) compared with the BD Veritor (74%, 95% CI 65-81%), CareStart (74%, 95% CI 65-81%) and Oscar Corona (74%, 95% CI 65-82%) lateral flow antigen tests. Antigen and viral culture positivity were also highly correlated with sample viral load, with areas under the receiver operator characteristic curves of 0.94 to 0.97 and 0.92, respectively. A viral load threshold of 100 000 copies/mL was 95% sensitive (95% CI, 90-98%) and 72% specific (95% CI, 60-81%) for predicting viral culture positivity. Adjusting for sample dilution inherent in our study design, sensitivities of antigen tests were ≥95% for detection of viral culture positive samples with viral loads >106 genome copies/mL, although specificity of antigen testing was imperfect.DiscussionAntigen testing results and viral culture were correlated. For culture positive samples, the sensitivity of antigen tests was high at high viral loads that are likely associated with significant infectivity. Therefore, our data provides support for use of antigen testing in ruling out infectivity at the time of sampling.
Project description:During the COVID-19 pandemic, lateral flow tests (LFTs) were used to regulate access to work, education, social activities, and travel. However, falsification of home LFT results was a concern. Falsification of test results during an ongoing pandemic is a sensitive issue. Consequently, respondents may not answer truthfully to questions about LFT falsification behaviours (FBs) when asked directly. Indirect questioning techniques such as the Extended Crosswise model (ECWM) can provide more reliable prevalence estimates of sensitive behaviors than direct questioning. Here we report the prevalence of LFT FBs in a representative sample in England (n = 1577) using direct questioning (DQ) and the ECWM. We examine the role of demographic and psychological variables as predictors of LFT FBs. We show that the prevalence estimates of the FBs in the DQ condition were significantly lower than the ECWM estimates, e.g., reporting a negative result without conducting a test: 5.7% DQ vs 18.4% ECWM. Moral norms, subjective norms, anticipated regret, perception of risk to self, and trust in government predicted some of the FBs. Indirect questioning techniques can help provide more realistic and higher quality data about compliance with behavioural regulations to government and public health agencies.
Project description:Within the successive waves that occurred during the SARS-CoV-2 pandemic, recommendations arose to test symptomatic and contact subjects by using rapid antigen devices directed against the viral nucleocapsid protein with the aim to isolate contagious patients without delay. The objective of this study was to evaluate the ability of four rapid lateral-flow tests (RLFT) that were commercially available on the French market in 2022 to recognize various strains of SARS-CoV-2. Series of five-fold dilutions of seven viral suspensions belonging to different lineages of SARS-CoV-2 (19A, 20A, Alpha, Beta, Gamma, Delta and Omicron) were used to evaluate the analytical sensitivity of four commercially available RLFTs (manufacturers: Abbott, AAZ, Becton-Dickinson and Biospeedia). Cell culture and quantitative RT-PCR were used as references. Excellent correlations were observed for each lineage strain between the viral titer obtained via cell culture and the number of RNA copies measured by quantitative RT-PCR. Although the four tests were able to recognize all the tested variants, significant differences in terms of sensitivity were observed between the four RLFTs. Despite the limitation represented by the small number of devices and clinical isolates that were tested, this study contributed by rapidly comparing the sensitivity of SARS-CoV-2 RLFTs in the Omicron era.
Project description:Inexpensive, simple, rapid diagnostics are necessary for efficient detection, treatment, and mitigation of COVID-19. Assays for SARS-CoV2 using reverse transcription polymerase chain reaction (RT-PCR) offer good sensitivity and excellent specificity, but are expensive, slowed by transport to centralized testing laboratories, and often unavailable. Antigen-based assays are inexpensive and can be rapidly mass-produced and deployed at point-of-care, with lateral flow assays (LFAs) being the most common format. While various manufacturers have produced commercially available SARS-Cov2 antigen LFAs, access to validated tests remains difficult or cost prohibitive in low-and middle-income countries. Herein, we present a visually read open-access LFA (OA-LFA) using commercially-available antibodies and materials for the detection of SARS-CoV-2. The LFA yielded a Limit of Detection (LOD) of 4 TCID50/swab of gamma irradiated SARS-CoV-2 virus, meeting the acceptable analytical sensitivity outlined by in World Health Organization target product profile. The open-source architecture presented in this manuscript provides a template for manufacturers around the globe to rapidly design a SARS-CoV2 antigen test.
Project description:Despite the widespread application of point-of-care lateral flow tests, the viscosity dependence of these assay results remains a significant challenge. Here, we employ centrifugal microfluidic flow control through the nitrocellulose membrane of the strip to eliminate the viscosity bias. The key feature is the balancing of the sample flow into the cassette of the lateral flow test with the air flow out of the cassette. A viscosity-independent flow rate of 3.01 ± 0.18 µl/min (±6%) is demonstrated for samples with viscosities ranging from 1.1 mPas to 24 mPas, a factor greater than 20. In a model human IgG lateral flow assay, signal-intensity shifts caused by varying the sample viscosity from 1.1 mPas to 2.3 mPas could be reduced by more than 84%.
Project description:This study evaluated the validity and utility of antigen-detection rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 in elite sports. The data on utility, ease of use and application for Ag-RDTs as a new testing format were positive from players and staff. This evaluation was limited by the low prevalence of SARS-CoV-2 circulating within the three squads. This study highlights the need for continued service evaluations for SARS-CoV-2 Ag-RDTs in elite sport settings.
Project description:The relationship between N-antigen concentration and viral load within and across different specimens guides the clinical performance of rapid diagnostic tests (RDT) in different uses. A prospective study was conducted in Porto Velho, Brazil, to investigate RDT performance in different specimen types as a function of the correlation between antigen concentration and viral load. The study included 214 close contacts with recent exposures to confirmed cases, aged 12 years and older and with various levels of vaccination. Antigen concentration was measured in nasopharyngeal swab (NPS), anterior nares swab (ANS), and saliva specimens. Reverse transcriptase (RT)-PCR was conducted on the NPS and saliva specimens, and two RDTs were conducted on ANS and one RDT on saliva. Antigen concentration correlated well with viral load when measured in the same specimen type but not across specimen types. Antigen levels were higher in symptomatic cases compared to asymptomatic/oligosymptomatic cases and lower in saliva compared to NPS and ANS samples. Discordant results between the RDTs conducted on ANS and the RT-PCR on NPS were resolved by antigen concentration values. The analytical limit-of-detection of RDTs can be used to predict the performance of the tests in populations for which the antigen concentration is known. The antigen dynamics across different sample types observed in SARS-CoV-2 disease progression support use of RDTs with nasal samples. Given lower antigen concentrations in saliva, rapid testing using saliva is expected to require improved RDT analytical sensitivity to achieve clinical sensitivity similar to rapid testing of nasal samples.