Unknown

Dataset Information

0

Giant Response and Selectivity of Hansen Solubility Parameters-Based Graphene-SBS Co-Polymer Matrix Composite Room Temperature Sensor to Organic Vapours.


ABSTRACT: A styrene-butadiene-styrene co-polymer matrix nanocomposite filled with graphene nanoplatelets was studied to prepare chemiresistive volatile organic compounds (VOCs) room temperature sensors with considerable response and selectivity. Nanofiller concentration was estimated from the electrical conductivity percolation behaviour of the nanocomposite. Fabricated sensors provided selective relative responses to representative VOCs differing by orders of magnitude. Maximum observed average relative responses upon exposure to saturated vapours of the tested VOCs were ca. 23% for ethanol, 1600% for acetone, and the giant values were 9 × 106% for n-heptane and 10 × 106% for toluene. The insensitivity of the sensor to the direct saturated water vapour exposure was verified. Although high humidity decreases the sensor's response, it paradoxically enhances the resolution between hydrocarbons and polar organics. The non-trivial sensing mechanism is explained using the Hansen solubility parameters (HSP), enabling a rational design of new sensors; thus, the HSP-based class of sensors is outlined.

SUBMITTER: Slobodian R 

PROVIDER: S-EPMC10857537 | biostudies-literature | 2024 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Giant Response and Selectivity of Hansen Solubility Parameters-Based Graphene-SBS Co-Polymer Matrix Composite Room Temperature Sensor to Organic Vapours.

Slobodian Rostislav R   Olejnik Robert R   Dmonte David John DJ   Sevcik Jakub J   Matyas Jiri J   Jurca Marek M   Pricilla R Blessy RB   Hanulikova Barbora B   Slobodian Petr P   Kuritka Ivo I  

Polymers 20240123 3


A styrene-butadiene-styrene co-polymer matrix nanocomposite filled with graphene nanoplatelets was studied to prepare chemiresistive volatile organic compounds (VOCs) room temperature sensors with considerable response and selectivity. Nanofiller concentration was estimated from the electrical conductivity percolation behaviour of the nanocomposite. Fabricated sensors provided selective relative responses to representative VOCs differing by orders of magnitude. Maximum observed average relative  ...[more]

Similar Datasets

| S-EPMC6678509 | biostudies-literature
| S-EPMC7019074 | biostudies-literature
| S-EPMC5725732 | biostudies-literature
| S-EPMC6210805 | biostudies-literature
| S-EPMC6643659 | biostudies-literature
| S-EPMC10459436 | biostudies-literature
| S-EPMC10865435 | biostudies-literature
| S-EPMC6682101 | biostudies-literature
| S-EPMC7827617 | biostudies-literature
| S-EPMC3948153 | biostudies-other