Project description:BackgroundAtrial tachyarrhythmias (ATs) are a major source of morbidity in the atrial septal defect (ASD) patient cohort. The optimal timing and approach of anti-arrhythmic intervention is currently unclear. Here, we sought to determine the overall rate of ATs following percutaneous ASD closure and risk factors that may predict this.MethodsA systematic search of the literature was performed using the search terms '(Secundum Atrial Septal Defects AND Atrial arrhythmias) AND (transcatheter closure or percutaneous closure or device closure)'. All studies in English reporting the rate of ATs following percutaneous closure of secundum ASDs in adult patients were included. The primary outcome was documented AT detection during follow-up ECG monitoring. A meta-regression was then performed to test for an interaction between demographic/procedural characteristics and the primary outcome.Results13 observational studies including 2366 patients were analysed. The overall post-procedure AT event detection rate was 8.6%. Multivariate meta-regression analysis revealed that only male gender was associated with a higher rate of post-procedure AT detection while utilisation of the Amplatzer Septal Occluder device was associated with a lower AT detection rate and comprised 96.2% of all devices used. A high level of heterogeneity was observed (I2-statistic 92.3%, Q value 156.8).ConclusionsOur study illustrates that despite percutaneous ASD closure, a high proportion of adult patients have ATs with male gender correlating with higher AT rates. While the Amplatzer Septal Occluder device correlated with lower AT rates, this was the overwhelmingly the predominant device used hence comparison to other devices remains challenging.
Project description:BackgroundWe report a case study of fat embolism seen on ultrasound at right internal jugular vein during central venous cannulation in a patient diagnosed with fat embolism syndrome. This case demonstrates the importance of ultrasound for evaluation of trauma cases with suspicion of fat embolism.Case presentationA 23-year-old trauma patient with closed fracture of left femoral shaft and left humerus presented to our emergency department (ED). 11 h after admission to ED, patient became confused, hypoxic and hypotensive. He was then intubated for respiratory failure and mechanically ventilated. Transesophageal ultrasound revealed hyperdynamic heart, dilated right ventricle with no regional wall abnormalities and no major aorta injuries. Whole-body computed tomography was normal. During central venous cannulation of right internal jugular vein (IJV), we found free floating mobile hyperechoic spots, located at the anterior part of the vein. A diagnosis of fat embolism syndrome later was made based on the clinical presentation of long bone fractures and fat globulin in the blood. Despite aggressive fluid resuscitation, patient was a non-responder and needed vasopressor infusion for persistent shock. Blood aspirated during cannulation from the IJV revealed a fat globule. Patient underwent uneventful orthopedic procedures and was discharged well on day 5 of admission.ConclusionsPoint-of-care ultrasound findings of fat embolism in central vein can facilitate and increase the suspicion of fat embolism syndrome.
Project description:BackgroundRight internal jugular vein (IJV) is a preferred access route for tunneled (cuffed) dialysis catheters (TDCs), and both right external jugular vein (EJV) and left IJV are alternative routes for patients in case the right IJV isn't available for TDC placement. This retrospective study aimed to determine if a disparity exists between the two alternative routes in hemodialysis patients in terms of outcomes of TDCs.Methods49 hemodialysis patients who required TDCs through right EJV (n = 21) or left IJV (n = 28) as long-term vascular access were included in this study. The primary end point was cumulative catheter patency. Secondary end points include primary catheter patency, proportion of patients that never required urokinase and incidence of catheter-related bloodstream infections (CRBSI).ResultsA total of 20,870 catheter-days were evaluated and the median was 384 (interquartile range, 262-605) catheter-days. Fewer catheters were removed in the right EJV group than in the left IJV group (P = 0.007). Mean cumulative catheter patency was higher in the right EJV group compared with the left IJV group (P = 0.031). There was no significant difference between the two groups in the incidence of CRBSI, primary catheter patency or proportion of patients that never required urokinase use. Total indwell time of antecedent catheters was identified as an independent risk factor for cumulative catheter patency by Cox regression hazards test with an HR of 2.212 (95% CI, 1.363-3.588; p = 0.001).ConclusionsRight EJV might be superior to left IJV as an alternative insertion route for TDC placement in hemodialysis patients whose right IJVs are unavailable.
Project description:Several devices have been designed and tried over the years to percutaneously close atrial septal defects (ASDs). Most of the devices were first experimented in animal models with subsequent clinical testing in human subjects. Some devices were discontinued or withdrawn from further clinical use for varied reasons and other devices received Food and Drug Administration (FDA) approval with consequent continued usage. The outcomes of both discontinued and currently used devices was presented in some detail. The results of device implantation are generally good when appropriate care and precautions are undertaken. At this time, Amplatzer Septal Occluder is most frequently utilized device for occlusion of secundum ASD around the world.
Project description:We developed technique similar to transcatheter treatment for superior sinus venosus defects to treat a patient with a Partial Anomalous Pulmonary Venous Connection of the right upper pulmonary veins (RUPV) without an atrial septal defect. A double transseptal puncture was performed, and the left atrium (LA) was connected with the RUPV using a covered stent. The blood flow from the superior vena cava was directed to the right atrium (RA) using a second covered stent.
Project description:BackgroundAlthough ultrasonography is recommended in internal jugular vein (IJV) catheterization, the landmark-guided technique should still be considered. The central landmark using the two heads of the sternocleidomastoid muscle is widely used, but it is inaccurate for IJV access. As an alternative landmark, we investigated the accuracy of the new landmark determined by inspection of the respiratory jugular venodilation and direct IJV palpation in right IJV access by ultrasonography.Methods and findingsThirty patients were enrolled. After induction of anesthesia, the central landmark was marked at the cricoid cartilage level (M1) and the alternative landmark determined by inspection of the respiratory jugular venodilation and direct palpation of IJV was also marked at the same level (M2). Using ultrasonography, the location of IJV was identified (M3) and the distance between M1 and M3 as well as between M2 and M3 were measured. The median (interquartile range) distance between the M2 and M3 was 3.5 (2.0-6.0) mm, compared to 17.5 (12.8-21.3) mm between M1 and M3. (P<0.001) The dispersion of distances between M2 and M3 was significantly smaller than between M1 and M3. (P<0.001) The visibility of respiratory jugular venodilation was associated with CVP more than 4 mmHg. Limitations of the present study are that the inter-observer variability was not investigated and that the visibility of the alternative landmark can be limited to right IJV in adults.ConclusionThe alternative landmark may allow shorter distance for the right side IJV access than the central landmark and can offer advantages in right IJV catheterization when ultrasound device is unavailable.Trial registrationClinical Research Informational Service KCT0000812.
Project description:BackgroundTranscatheter closure of atrial septal defects (ASDs) is well-established. However, this procedure can be challenging, requiring multiple attempts and advanced implantation maneuvers.Materials and methodsFrom July 2019 to July 2022, patients to whom the fast atrial sheath traction (FAST) technique was applied for ASD device closure were prospectively followed up. The device was rapidly unsheathed in the middle of the left atrium (LA) to let it clamp the ASD from both sides simultaneously. This novel technique was directly applied in patients with absent aortic rims and/or ASD size-to-body weight ratio higher than 0.9 or after failed attempts of standard implantation.ResultsSeventeen patients (64.7% males) were involved with a median age of 9.8 years [interquartile range (IQR), 7.6-15.1] and a median weight of 34 kg (IQR, 22-44). The median ASD size on ultrasound was 19 mm (IQR, 16-22). Five (29.4%) patients had absent aortic rims, and three (17.6%) patients had an ASD size-to-body weight ratio higher than 0.9. The median device size was 22 mm (IQR, 17-24). The median difference between device size and ASD two-dimensional static diameter was 3 mm (IQR, 1-3). All interventions were straightforward without any complications using three different occluder devices. One device was removed before release and upsized to the next size. The median fluoroscopy time was 4.1 min (IQR, 3.6-4.6). All patients were discharged the next postoperative day. On a median follow-up of 13 months (IQR, 8-13), no complications were detected. All patients achieved full clinical recovery with complete shunt closure.ConclusionWe present a new implantation technique to efficiently close simple and complex ASDs. The FAST technique can be of benefit in overcoming left disc malalignment to the septum in defects with absent aortic rims and in avoiding complex implantation maneuvers and the risks of injuring the pulmonary veins.