Ultrafast longitudinal imaging of haemodynamics via single-shot volumetric photoacoustic tomography with a single-element detector.


ABSTRACT: Techniques for imaging haemodynamics use ionizing radiation or contrast agents or are limited by imaging depth (within approximately 1 mm), complex and expensive data-acquisition systems, or low imaging speeds, system complexity or cost. Here we show that ultrafast volumetric photoacoustic imaging of haemodynamics in the human body at up to 1 kHz can be achieved using a single laser pulse and a single element functioning as 6,400 virtual detectors. The technique, which does not require recalibration for different objects or during long-term operation, enables the longitudinal volumetric imaging of haemodynamics in vasculature a few millimetres below the skin's surface. We demonstrate this technique in vessels in the feet of healthy human volunteers by capturing haemodynamic changes in response to vascular occlusion. Single-shot volumetric photoacoustic imaging using a single-element detector may facilitate the early detection and monitoring of peripheral vascular diseases and may be advantageous for use in biometrics and point-of-care testing.

SUBMITTER: Zhang Y 

PROVIDER: S-EPMC11136871 | biostudies-literature | 2024 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrafast longitudinal imaging of haemodynamics via single-shot volumetric photoacoustic tomography with a single-element detector.

Zhang Yide Y   Hu Peng P   Li Lei L   Cao Rui R   Khadria Anjul A   Maslov Konstantin K   Tong Xin X   Zeng Yushun Y   Jiang Laiming L   Zhou Qifa Q   Wang Lihong V LV  

Nature biomedical engineering 20231130 6


Techniques for imaging haemodynamics use ionizing radiation or contrast agents or are limited by imaging depth (within approximately 1 mm), complex and expensive data-acquisition systems, or low imaging speeds, system complexity or cost. Here we show that ultrafast volumetric photoacoustic imaging of haemodynamics in the human body at up to 1 kHz can be achieved using a single laser pulse and a single element functioning as 6,400 virtual detectors. The technique, which does not require recalibra  ...[more]

Similar Datasets

| S-EPMC10055152 | biostudies-literature
| S-EPMC10661598 | biostudies-literature
| S-EPMC10042990 | biostudies-literature
| S-EPMC11828441 | biostudies-literature
| S-EPMC10161092 | biostudies-literature
| S-EPMC9531840 | biostudies-literature
| S-EPMC7190645 | biostudies-literature
| S-EPMC7226881 | biostudies-literature
| S-EPMC9811490 | biostudies-literature
| S-EPMC9577133 | biostudies-literature