Project description:The simplest and most commonly used acoustic levitator is comprised of a transmitter and an opposing reflecting surface. This type of device, however, is only able to levitate objects along one direction, at distances multiple of half of a wavelength. In this work, we show how a customised reflective acoustic metamaterial enables the levitation of multiple particles, not necessarily on a line and with arbitrary mutual distances, starting with a generic input wave. We establish a heuristic optimisation technique for the design of the metamaterial, where the local height of the surface is used to introduce delay patterns to the reflected signals. Our method stands for any type and number of sources, spatial resolution of the metamaterial and system's variables (i.e. source position, phase and amplitude, metamaterial's geometry, relative position of the levitation points, etc.). Finally, we explore how the strength of multiple levitation points changes with their relative distance, demonstrating sub-wavelength field control over levitating polystyrene beads into various configurations.
Project description:Engineering tissue structures that mimic those found in vivo remains a challenge for modern biology. We demonstrate a new technique for engineering composite structures of cells comprising layers of heterogeneous cell types. An acoustofluidic bioreactor is used to assemble epithelial cells into a sheet-like structure. On transferring these cell sheets to a confluent layer of fibroblasts, the epithelial cells cover the fibroblast surface by collective migration maintaining distinct epithelial and fibroblast cell layers. The collective behaviour of the epithelium is dependent on the formation of cell-cell junctions during levitation and contrasts with the behaviour of mono-dispersed epithelial cells where cell-matrix interactions dominate and hinder formation of discrete cell layers. The multilayered tissue model is shown to form a polarised epithelial barrier and respond to apical challenge. The method is useful for engineering a wide range of layered tissue types and mechanistic studies on collective cell migration.
Project description:This paper proposes a metasurface design approach with perforated labyrinthine path coil structure to manipulate the acoustic transmission with inexpensive materials. The medium in the labyrinthine path coils in this design is air, but not limited to air. A systematic approach has been proposed for the unit cell design of acoustic metamaterials with adjustable resonance peak frequencies and bandgap width. The theory demonstrates that the length of pipe segments determines resonance peak frequencies and the cross-sectional area ratio adjusts the bandgap width. The proposed design approach uses an equivalent pipe circuit based analytical model to design the high transmission (high pass) and high reflection (low pass) unit cell. The simulation and experiment has been performed to evaluate the validity of the theory. Although there exists some assumptions in the theory, the theory still has enough accuracy to guide the metasurface design illustrated by the simulation and experiment results.
Project description:Acoustic levitation supplies a containerless state to eliminate natural convection and heterogeneous crystal nucleation and thus provides a highly uniform and ultra clean condition in the confined levitating area. Herein, we attempt to make full use of these advantages to fabricate well dispersed metal nanoparticles. The gold nanoparticles, synthesized in an acoustically levitated droplet, exhibited a smaller size and improved catalytic performance in 4-nitrophenol reduction were synthesized in an acoustically levitated droplet. The sound field was simulated to understand the impact of acoustic levitation on gold nanoparticle growth with the aid of crystal growth theory. Chemical reducing reactions in the acoustic levitated space trend to occur in a better dispersed state because the sound field supplies continuous vibration energy. The bubble movement and the cavitation effect accelerate the nucleation, decrease the size, and the internal flow inside levitated droplet probably inhibit the particle fusion in the growth stage. These factors lead to a reduction in particle size compared with the normal wet chemical synthetic condition. The resultant higher surface area and more numerous active catalytic sites contribute to the improvement of the catalytic performance.
Project description:In recent years, 3D cell culture models such as spheroid or organoid technologies have known important developments. Many studies have shown that 3D cultures exhibit better biomimetic properties compared to 2D cultures. These properties are important for in-vitro modeling systems, as well as for in-vivo cell therapies and tissue engineering approaches. A reliable use of 3D cellular models still requires standardized protocols with well-controlled and reproducible parameters. To address this challenge, a robust and scaffold-free approach is proposed, which relies on multi-trap acoustic levitation. This technology is successfully applied to Mesenchymal Stem Cells (MSCs) maintained in acoustic levitation over a 24-h period. During the culture, MSCs spontaneously self-organized from cell sheets to cell spheroids with a characteristic time of about 10 h. Each acoustofluidic chip could contain up to 30 spheroids in acoustic levitation and four chips could be ran in parallel, leading to the production of 120 spheroids per experiment. Various biological characterizations showed that the cells inside the spheroids were viable, maintained the expression of their cell surface markers and had a higher differentiation capacity compared to standard 2D culture conditions. These results open the path to long-time cell culture in acoustic levitation of cell sheets or spheroids for any type of cells.
Project description:Usually, we must use an appropriate support material to keep the metal species stable and finely dispersed as supported metal nanoparticles for industry application. Therefore, the choice of support material is a key factor in determining the dispersion and particle size of the noble metal species. Here, we report the synthesis of a single-atom Pt material in the solution and supported Pt nanoclusters on microporous La2O3 by a one-step acoustic levitation method without any pretreatment/modification of raw oxide. We have strongly contributed to the synthetic methodology of the surface/interfacial heterogeneous catalysts in this study, and this finding could open another door for synthesis of supported metal nanoparticles on porous materials for environmental catalysis.
Project description:Acoustic manipulation by an ultrasonic phased array provides an entirely new approach to processes such as coalescence, mixing, separation, and evaporation occurring in the generation of new materials, physical property measurement, the biomedical industry, etc. However, to date, ultrasonic phased arrays have not been fully investigated for applications in fluid manipulation. This paper provides contactless coalescence and mixing techniques for droplets in air by controlling the acoustic potential by using an ultrasonic phased array. We focused on mode oscillation to propose an efficient mixing technique for liquid without contact. A comparison of mixing performance between cases with mode oscillation and without mode oscillation showed that the flow induced by mode oscillation promotes droplet mixing. Our paper demonstrates the feasibility of contactless coalescence and mixing as a first step in fluid manipulation with a phased array.
Project description:Macromolecular Crystallography is a powerful and valuable technique to assess protein structures. Samples are commonly cryogenically cooled to minimise radiation damage effects from the X-ray beam, but low temperatures hinder normal protein functions and this procedure can introduce structural artefacts. Previous experiments utilising acoustic levitation for beamline science have focused on Langevin horns which deliver significant power to the confined droplet and are complex to set up accurately. In this work, the low power, portable TinyLev acoustic levitation system is used in combination with an approach to dispense and contain droplets, free of physical sample support to aid protein crystallography experiments. This method facilitates efficient X-ray data acquisition in ambient conditions compatible with dynamic studies. Levitated samples remain free of interference from fixed sample mounts, receive negligible heating, do not suffer significant evaporation and since the system occupies a small volume, can be readily installed at other light sources.
Project description:When focused ultrasound waves of moderate intensity in liquid encounter an air interface, a chain of drops emerges from the liquid surface to form what is known as a drop-chain fountain. Atomization, or the emission of micro-droplets, occurs when the acoustic intensity exceeds a liquid-dependent threshold. While the cavitation-wave hypothesis, which states that atomization arises from a combination of capillary-wave instabilities and cavitation bubble oscillations, is currently the most accepted theory of atomization, more data on the roles of cavitation, capillary waves, and even heat deposition or boiling would be valuable. In this paper, we experimentally test whether bubbles are a significant mechanism of atomization in drop-chain fountains. High-speed photography was used to observe the formation and atomization of drop-chain fountains composed of water and other liquids. For a range of ultrasonic frequencies and liquid sound speeds, it was found that the drop diameters approximately equalled the ultrasonic wavelengths. When water was exchanged for other liquids, it was observed that the atomization threshold increased with shear viscosity. Upon heating water, it was found that the time to commence atomization decreased with increasing temperature. Finally, water was atomized in an overpressure chamber where it was found that atomization was significantly diminished when the static pressure was increased. These results indicate that bubbles, generated by either acoustic cavitation or boiling, contribute significantly to atomization in the drop-chain fountain.
Project description:X-ray free-electron lasers (XFELs) provide very intense X-ray pulses suitable for macromolecular crystallography. Each X-ray pulse typically lasts for tens of femtoseconds and the interval between pulses is many orders of magnitude longer. Here we describe two novel acoustic injection systems that use focused sound waves to eject picoliter to nanoliter crystal-containing droplets out of microplates and into the X-ray pulse from which diffraction data are collected. The on-demand droplet delivery is synchronized to the XFEL pulse scheme, resulting in X-ray pulses intersecting up to 88% of the droplets. We tested several types of samples in a range of crystallization conditions, wherein the overall crystal hit ratio (e.g., fraction of images with observable diffraction patterns) is a function of the microcrystal slurry concentration. We report crystal structures from lysozyme, thermolysin, and stachydrine demethylase (Stc2). Additional samples were screened to demonstrate that these methods can be applied to rare samples.