Project description:Far ultraviolet-C irradiation at 222 nm has potent bactericidal effects against severe infections such as peritonitis, with minimal cytotoxicity. Bacterial peritonitis due to bowel perforation is a serious condition with high mortality despite current treatments. This study investigated the safety and efficacy of intraperitoneal far ultraviolet-C irradiation at 222 nm. In vitro experiments optimized the fluid conditions for bacterial or protein concentrations prior to in vivo evaluation. In vivo efficacy was assessed in a rat peritonitis model induced by Escherichia coli, measuring intra-abdominal bacterial concentration, blood cytokine levels, and mortality rates. Safety was evaluated by analyzing cyclobutane pyrimidine dimers as markers of DNA damage in five abdominal organs: stomach, small intestine, colon, liver, and spleen. Statistical analyses employed parametric methods for normally distributed data and non-parametric methods for data without normality. Optimal in vitro conditions included 106 CFU/mL bacteria, 0.5 mW/cm2 irradiation, and 10-3 mg/mL protein. In the rat model, far ultraviolet-C irradiation at 222 nm significantly decreased intra-abdominal bacteria, reduced blood cytokines (interleukin-1β and interleukin-6), and elevated survival rates from 20% to 60%, compared to lavage alone. The formation of cyclobutane pyrimidine dimers was significantly lower with 222 nm irradiation than with 254 nm, suggesting reduced DNA damage. These findings indicate that far ultraviolet-C irradiation at 222 nm, when combined with lavage, represents a promising therapeutic strategy for bacterial peritonitis, providing effective bacterial reduction and a favorable safety profile. Further research is needed to verify these findings and investigate long-term safety and potential clinical applications.
Project description:Highlights • 222-nm UVC light (0.1 mW/cm2) reduced viable SARS-CoV-2 by 0.94 log10 in 10 seconds.• 222-nm UVC light (0.1 mW/cm2) reduced viable SARS-CoV-2 by 2.51 log10 in 30 seconds.• 222-nm UVC light did not reduce SARS-CoV-2 RNA copy number after 5-minute irradiation.• TSID50 and not RT-qPCR should be used to monitor far-UVC disinfection of surfaces. Background Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), has emerged as a serious threat to human health worldwide. Efficient disinfection of surfaces contaminated with SARS-CoV-2 may help prevent its spread. This study aimed to investigate the in vitro efficacy of 222-nm far-ultraviolet light (UVC) on the disinfection of SARS-CoV-2 surface contamination. Methods We investigated the titer of SARS-CoV-2 after UV irradiation (0.1 mW/cm2) at 222 nm for 10-300 seconds using the 50% tissue culture infectious dose (TCID50). In addition, we used quantitative reverse transcription polymerase chain reaction to quantify SARS-CoV-2 RNA under the same conditions. Results One and 3 mJ/cm2 of 222-nm UVC irradiation (0.1 mW/cm2 for 10 and 30 seconds) resulted in 88.5 and 99.7% reduction of viable SARS-CoV-2 based on the TCID50 assay, respectively. In contrast, the copy number of SARS-CoV-2 RNA did not change after UVC irradiation even after a 5-minute irradiation. Conclusions This study shows the efficacy of 222-nm UVC irradiation against SARS-CoV-2 contamination in an in vitro experiment. Further evaluation of the safety and efficacy of 222-nm UVC irradiation in reducing the contamination of real-world surfaces and the potential transmission of SARS-CoV-2 is needed.
Project description:Devices using 222 nm germicidal ultraviolet light (GUV222) have been marketed to reduce virus transmission indoors with low risk of occupant harm from direct UV exposure. GUV222 generates ozone, an indoor air pollutant and oxidant, under constrained laboratory conditions, but the chemistry byproducts of GUV222-generated ozone in real indoor spaces is uncharacterized. We deployed GUV222 in a public restroom, with an air change rate of 1 h-1 one weekend and 2 h-1 the next, to measure ozone formation and byproducts generated from ozone chemistry indoors. Ozone from GUV222 increased background concentrations by 5 ppb on average for both weekends and reacted rapidly (e.g., at rates of 3.7 h-1 for the first weekend and 2.0 h-1 for the second) with gas-phase precursors emitted by urinal screens and on surfaces. These ozone reactions generated volatile organic compound and aerosol byproducts (e.g., up to 2.6 μg m-3 of aerosol mass). We find that GUV222 is enhancing indoor chemistry by at least a factor of two for this restroom. The extent of this enhanced chemistry will likely be different for different indoor spaces and is dependent upon ventilation rates, species and concentrations of precursor VOCs, and surface reactivity. Informed by our measurements of ozone reactivity and background aerosol concentrations, we present a framework for predicting aerosol byproduct formation from GUV222 that can be extended to other indoor spaces. Further research is needed to understand how typical uses of GUV222 could impact air quality in chemically diverse indoor spaces and generate indoor air chemistry byproducts that can affect human health.
Project description:Since the 1930s, germicidal ultraviolet (GUV) irradiation has been used indoors to prevent the transmission of airborne diseases, such as tuberculosis and measles. Recently, it has received renewed attention due to the COVID-19 pandemic. While GUV radiation has been shown to be effective in inactivating airborne bacteria and viruses, few studies on the impact of GUV on indoor air quality have been published. In this work, we evaluate the effects of GUV222 (GUV at 222 nm) on the chemistry of a common indoor volatile organic compound (VOC), limonene. We found that the production of O3 by the GUV222 lamps caused the formation of particulate matter (PM) and oxygenated volatile organic compounds (VOCs). We also found that the chemistry proceeds through the ozonolysis of limonene as well as the reaction with secondary OH, and that the presence of GUV light led to observable but small perturbations to this chemistry. Understanding the effects of GUV222 on indoor air quality is important in evaluating the safety of these devices.
Project description:Krypton chloride (KrCl*) excilamps emitting at far-UVC 222 nm represent a promising technology for microbial disinfection and advanced oxidation of organic micropollutants (OMPs) in water treatment. However, direct photolysis rates and photochemical properties at 222 nm are largely unknown for common OMPs. In this study, we evaluated photolysis for 46 OMPs by a KrCl* excilamp and compared it with a low-pressure mercury UV lamp. Generally, OMP photolysis was greatly enhanced at 222 nm with fluence rate-normalized rate constants of 0.2-21.6 cm2·μEinstein-1, regardless of whether they feature higher or lower absorbance at 222 nm than at 254 nm. The photolysis rate constants and quantum yields were 10-100 and 1.1-47 times higher, respectively, than those at 254 nm for most OMPs. The enhanced photolysis at 222 nm was mainly caused by strong light absorbance for non-nitrogenous, aniline-like, and triazine OMPs, while notably higher quantum yield (4-47 times of that at 254 nm) occurred for nitrogenous OMPs. At 222 nm, humic acid can inhibit OMP photolysis by light screening and potentially by quenching intermediates, while nitrate/nitrite may contribute more than others to screen light. Overall, KrCl* excilamps are promising in achieving effective OMP photolysis and merit further research.
Project description:In recent years, there has been a gradual increase in the prevalence of drug-resistant bacteria, primarily attributed to the widespread use of antibiotics. This has resulted in heightened mortality rates, morbidity, and exorbitant healthcare costs associated with antibiotic-resistant bacterial infections. In order to mitigate the spread of antibiotic-resistant bacteria, environmental disinfection plays a crucial role. Ultraviolet radiation C (UVC) light disinfection has emerged as a potent technique to limit the transmission of nosocomial pathogens and prevent healthcare-associated infections. Different types of high-touch surfaces were used. A serial disinfected experiment with different 222 nm UVC dosages was conducted on clinically isolated antibiotic-resistant bacteria, including methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus species (VRE), carbapenem-resistant Escherichia coli (CREC), carbapenem-resistant Klebsiella pneumonia (CRKP), carbapenem-resistant Acinetobacter baumannii (CRAB), and carbapenem-resistant Pseudomonas aeruginosa (CRPA) on different material surfaces. The bactericidal efficacy was evaluated by The Clinical & Laboratory Standards Institute (CLSI) guidelines. 222 nm UVC irradiation had a potent bactericidal efficacy on clinical antibiotic-resistant bacteria on different high-touch surfaces that are commonly found in the environment and healthcare facilities. 222 nm UVC irradiation time was tested from 10 s to 1 h. Different surfaces affect the efficiency of 222 nm UVC. The more adsorptive a material is, the higher the dosage of 222 nm UVC irradiation energy is required for effective disinfection. The use of 222 nm UVC lamps for disinfection on different materials has been shown to be a useful method. However, it is crucial to pay attention to the energy required for effective sterilization.ImportanceThis study is crucial, providing compelling evidence on Far-ultraviolet radiation C (Far-UVC) light's efficacy against clinically significant antibiotic-resistant bacteria-a pressing issue in microbiology and infection control. Our research employs antibiotic-resistant strains from clinically isolated bacteria, emphasizing real-world relevance. Simultaneously, we assess Far-UVC light (222 nm) across diverse material surfaces commonly found in clinical settings. This dual approach ensures practical applicability and broad relevance. Our comprehensive setup and rigorous methodologies unequivocally demonstrate Far-UVC light's potency in combating antibiotic-resistant bacteria. Since 222 nm far-UVC has a disinfection capability and is harmless to mammalian cells, this dual effectiveness positions Far-UVC as a secure tool for infection control, with potential applications in healthcare settings, mitigating antibiotic-resistant bacteria spread, and reducing healthcare-associated infections.
Project description:An emerging intervention for control of airborne-mediated pandemics and epidemics is whole-room far-UVC (200-235 nm). Laboratory studies have shown that 222-nm light inactivates airborne pathogens, potentially without harm to exposed occupants. While encouraging results have been reported in benchtop studies and in room-sized bioaerosol chambers, there is a need for quantitative studies of airborne pathogen reduction in occupied rooms. We quantified far-UVC mediated reduction of aerosolized murine norovirus (MNV) in an occupied mouse-cage cleaning room within an animal-care facility. Benchtop studies suggest that MNV is a conservative surrogate for airborne viruses such as influenza and coronavirus. Using four 222-nm fixtures installed in the ceiling, and staying well within current recommended regulatory limits, far-UVC reduced airborne infectious MNV by 99.8% (95% CI: 98.2-99.9%). Similar to previous room-sized bioaerosol chamber studies on far-UVC efficacy, these results suggest that aerosolized virus susceptibility is significantly higher in room-scale tests than in bench-scale laboratory studies. That said, as opposed to controlled laboratory studies, uncertainties in this study related to airflow patterns, virus residence time, and dose to the collected virus introduce uncertainty into the inactivation estimates. This study is the first to directly demonstrate far-UVC anti-microbial efficacy against airborne pathogens in an occupied indoor location.
Project description:Far-UVC radiation, defined in this paper as ultraviolet (UV) radiation with wavelengths from 200 to 235 nm, is a promising tool to help prevent the spread of disease. The unique advantage of far-UVC technology over traditional UV germicidal irradiation lies in the potential for direct application of far-UVC into occupied spaces since antimicrobial doses of far-UVC are significantly below the recommended daily safe exposure limits. This study used a ceiling-mounted far-UVC fixture emitting at 222 nm to directly irradiate an indoor space and then evaluated the doses received upon a manikin. Radiation-sensitive film was affixed to the head, nose, lip and eyes of the manikin, and the 8-h equivalent exposure dose was determined. Variables examined included manikin height (sitting or standing position), manikin offset from directly below the fixture, tilt of the manikin, the addition of glasses, the addition of hair and different anatomical feature sizes. Importantly, at the manikin position with the highest dose to eyes, the average eye dose was only 5.8% of the maximum directly measured dose. These results provide the first experimental analysis of possible exposure doses a human would experience from an indoor far-UVC installation.
Project description:Far-ultraviolet radiation C light (far-UVC; 222 nm wavelength) has received attention as a safer light for killing pathogenic bacteria and viruses, as no or little DNA damage is observed after irradiation in mammalian skin models. Far-UVC does not penetrate deeply into tissues; therefore, it cannot reach the underlying critical basal cells. However, it was unclear whether far-UVC (222-UVC) irradiation could cause more biological damage at shallower depths than the 254 nm UVC irradiation (254-UVC), which penetrates more deeply. This study investigated the biological effects of 222- and 254-UVC on the small and transparent model organism Caenorhabditis elegans. At the same energy level of irradiation, 222-UVC introduced slightly less cyclobutane pyrimidine dimer damage to naked DNA in solution than 254-UVC. The survival of eggs laid during 0-4 h after irradiation showed a marked decrease with 254-UVC but not 222-UVC. In addition, defect of chromosomal condensation was observed in a full-grown oocyte by 254-UVC irradiation. In contrast, 222-UVC had a significant effect on the loss of motility of C. elegans. The sensory nervous system, which includes dopamine CEP and PVD neurons on the body surface, was severely damaged by 222-UVC, but not by the same dose of 254-UVC. Interestingly, increasing 254-UVC irradiation by about 10-fold causes similar damage to CEP neurons. These results suggest that 222-UVC is less penetrating, so energy transfer occurs more effectively in tissues near the surface, causing more severe damage than 254-UVC.
Project description:One strategy for mitigating the indoor transmission of airborne pathogens, including the SARS-CoV-2 virus, is irradiation by germicidal UV light (GUV). A particularly promising approach is 222 nm light from KrCl excimer lamps (GUV222); this inactivates airborne pathogens and is thought to be relatively safe for human skin and eye exposure. However, the impact of GUV222 on the composition of indoor air has received little experimental study. Here, we conduct laboratory experiments in a 150 L Teflon chamber to examine the formation of secondary species by GUV222. We show that GUV222 generates ozone (O3) and hydroxyl radicals (OH), both of which can react with volatile organic compounds to form oxidized volatile organic compounds and secondary organic aerosol particles. Results are consistent with a box model based on the known photochemistry. We use this model to simulate GUV222 irradiation under more realistic indoor air scenarios and demonstrate that under some conditions, GUV222 irradiation can lead to levels of O3, OH, and secondary organic products that are substantially elevated relative to normal indoor conditions. The results suggest that GUV222 should be used at low intensities and in concert with ventilation, decreasing levels of airborne pathogens while mitigating the formation of air pollutants.