Unknown

Dataset Information

0

Modified transport medium for improving influenza virus detection.


ABSTRACT:

Background

Accurate detection of influenza virus in clinical samples requires correct execution of all aspects of the detection test. If the viral load in a sample is below the detection limit, a false negative result may be obtained. To overcome this issue, we developed a modified transport medium (MTM) for clinical sample transportation to increase viral detection sensitivity.

Method

We first validated the MTM using laboratory-stocked influenza A viruses (IAVs: H1N1, H3N2, H7N3, H9N2) and influenza B viruses (IBVs: Yamagata, Victoria). We also tested clinical samples. A total of 110 patients were enrolled and a pair of samples were collected to determine the sensitivity of real-time polymerase chain reaction (RT-PCR) following MTM treatment.

Result

After 24 h culturing in MTM, the viral loads were increased, represented by a 10-fold increase in detection sensitivity for H1N1, H9N2, and IBVs, a 100-fold increase for H3N2, and a 1,000-fold increase for H7N3. We further tested the effects of MTM on 19 IAV and 11 IBV stored clinical samples. The RT-PCR results showed that the positive detection rate of IAV samples increased from 63.16% (12/19) without MTM culturing to 78.95% (15/19) after 48 h culturing, and finally 89.47% (17/19) after 72 h culturing. MTM treatment of IBV clinical samples also increased the positive detection rate from 36.36% (4/11, 0 h) to 63.64% (7/11, 48 h) to 72.73% (8/11, 72 h). For clinical samples detected by RT-PCR, MTM outperformed other transport mediums in terms of viral detection rate (11.81% increase, P=0.007).

Conclusion

Our results demonstrated that the use of MTM for clinical applications can increase detection sensitivity, thus facilitating the accurate diagnosis of influenza infection.

SUBMITTER: Zeng Z 

PROVIDER: S-EPMC11254831 | biostudies-literature | 2024

REPOSITORIES: biostudies-literature

altmetric image

Publications

Modified transport medium for improving influenza virus detection.

Zeng Zhiqi Z   Li Qianying Q   Guo Hua H   Liu Yong Y   Liang Lixi L   Lai Yuanfang Y   Fang Yi Y   Li Lei L   Xue Qiuting Q   Zhan Yangqing Y   Lin Zhengshi Z   Guan Wenda W   Yang Zifeng Z  

Frontiers in cellular and infection microbiology 20240704


<h4>Background</h4>Accurate detection of influenza virus in clinical samples requires correct execution of all aspects of the detection test. If the viral load in a sample is below the detection limit, a false negative result may be obtained. To overcome this issue, we developed a modified transport medium (MTM) for clinical sample transportation to increase viral detection sensitivity.<h4>Method</h4>We first validated the MTM using laboratory-stocked influenza A viruses (IAVs: H1N1, H3N2, H7N3,  ...[more]

Similar Datasets

| S-EPMC11820836 | biostudies-literature
| S-EPMC5691202 | biostudies-literature
| S-EPMC9280445 | biostudies-literature
| S-EPMC4710576 | biostudies-literature
| S-EPMC3814596 | biostudies-literature
| S-EPMC10782970 | biostudies-literature
| S-EPMC2528172 | biostudies-literature
| S-EPMC3122761 | biostudies-literature
| S-EPMC6105651 | biostudies-literature
| S-EPMC4057169 | biostudies-literature