Evaluation of tricuspid valve regurgitation following transvenous rotational mechanical lead extraction.


ABSTRACT:

Aims

Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes.

Methods and results

In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003-1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004-1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44-18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01-5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06-4.89; P = 0.035).

Conclusion

Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.

SUBMITTER: Migliore F 

PROVIDER: S-EPMC11282457 | biostudies-literature | 2024 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of tricuspid valve regurgitation following transvenous rotational mechanical lead extraction.

Migliore Federico F   Pittorru Raimondo R   De Lazzari Manuel M   Dall'Aglio Pietro Bernardo PB   Cecchetto Antonella A   Previtero Marco M   Pergola Valeria V   Thiene Gaetano G   Masiero Giulia G   Tarantini Giuseppe G   Tarzia Vincenzo V   Gerosa Gino G  

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 20240701 7


<h4>Aims</h4>Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes.<h4>Methods and results</h4>In 158 patients (mean age 66 ± 16.9 years) u  ...[more]

Similar Datasets

| S-EPMC8441198 | biostudies-literature
| S-EPMC8745716 | biostudies-literature
| S-EPMC5418555 | biostudies-literature
| S-EPMC4455541 | biostudies-literature
| S-EPMC10692839 | biostudies-literature
| S-EPMC9295692 | biostudies-literature
| S-EPMC8183877 | biostudies-literature
| S-EPMC8764071 | biostudies-literature
| S-EPMC11781887 | biostudies-literature
| S-EPMC10410196 | biostudies-literature