Unknown

Dataset Information

0

Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study.


ABSTRACT:

Background/aims

The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO).

Methods

Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our institution from January 2016 to December 2021 were compared.

Results

Sixty-two patients underwent EUS-HGS using PCSEMS (5/20-mm uncovered portions: 32/30). Stent migration occurred only in the 5-mm group. There were no differences in RBO rates (28.1% vs. 40.0%) or median time to RBO (6.8 vs. 7.1 months) between the two groups. Median overall survival (OS) was longer in the 20-mm group (3.1 vs. 4.9 months, p=0.037) due to the higher number of patients that resumed chemotherapy after EUS-HGS (56.7% vs. 28.1%, p=0.029). Good performance status, absence of hepatic metastases, and chemotherapy after EUS-HGS were independent predictors of longer OS.

Conclusions

No migration was observed in patients treated with PCSEMS with 20-mm uncovered portions. Patients treated with PCSEMS with 20-mm uncovered portions performed at least as well as those treated with 5-mm uncovered portions in all material respects.

SUBMITTER: Okamoto T 

PROVIDER: S-EPMC11294857 | biostudies-literature | 2024 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study.

Okamoto Takeshi T   Sasaki Takashi T   Takeda Tsuyoshi T   Hirai Tatsuki T   Ishitsuka Takahiro T   Yamada Manabu M   Nakagawa Hiroki H   Mie Takafumi T   Furukawa Takaaki T   Kasuga Akiyoshi A   Ozaka Masato M   Sasahira Naoki N  

Clinical endoscopy 20240510 4


<h4>Background/aims</h4>The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO).<h4>Methods</h4>Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our  ...[more]

Similar Datasets

| S-EPMC8357580 | biostudies-literature
| S-EPMC4747571 | biostudies-literature
| S-EPMC8045022 | biostudies-literature
| S-EPMC4798835 | biostudies-other
| S-EPMC8329149 | biostudies-literature
| S-EPMC9473849 | biostudies-literature
| S-EPMC10984750 | biostudies-literature
| S-EPMC10729169 | biostudies-literature
| S-EPMC10861805 | biostudies-literature
| S-EPMC11524840 | biostudies-literature