Unknown

Dataset Information

0

Bottle-in-bottle reaction device: Portable gas pressure meter for rapid and on-site analysis of oxalate in spinach and tea beverages.


ABSTRACT: A gas pressure meter-based portable/miniaturized analytical kit was established for rapid and on-site detection of oxalate. Potassium permanganate (KMnO4) and oxalate solution were mixed together in bottle-in-bottle reaction device, a simple oxidation reaction process occurred within 6 min and carbon dioxide (CO2) was generated, inducing the pressure of the sealed bottle changed, which was measured by a portable gas pressure meter. A detectable range of 0.1-6 μmol mL-1 and a detection limit of 0.064 μmol mL-1 were achieved. The proposed analytical method was further used for the analysis of several real samples (spinach, beverages and water samples), with the recoveries of 89-111%. Considering the interferences from the complicated matrix, calcium chloride (CaCl2) was served as a precipitant, oxalate (C2O4 2-) was precipitated with Ca2+ to form precipitation (CaC2O4), CaC2O4 was then separated from the matrix by centrifuge/filter, eliminating the interferences. It is a rapid, easy-used and interference-free analytical system/device for oxalate on-site and real time analysis.

SUBMITTER: Tang J 

PROVIDER: S-EPMC11305198 | biostudies-literature | 2024 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Bottle-in-bottle reaction device: Portable gas pressure meter for rapid and on-site analysis of oxalate in spinach and tea beverages.

Tang Jiayuan J   Zhuo Dali D   Dong Xiaoyu X   Xiao Jing J   Zhang Shu S   Xiong Xiaoli X   Tan Chao C   Zou Zhirong Z  

Food chemistry: X 20240711


A gas pressure meter-based portable/miniaturized analytical kit was established for rapid and on-site detection of oxalate. Potassium permanganate (KMnO<sub>4</sub>) and oxalate solution were mixed together in bottle-in-bottle reaction device, a simple oxidation reaction process occurred within 6 min and carbon dioxide (CO<sub>2</sub>) was generated, inducing the pressure of the sealed bottle changed, which was measured by a portable gas pressure meter. A detectable range of 0.1-6 μmol mL<sup>-1  ...[more]

Similar Datasets

| S-EPMC7186902 | biostudies-literature
| S-EPMC8513091 | biostudies-literature
| S-EPMC6100029 | biostudies-literature
2021-05-18 | GSE146711 | GEO
| S-EPMC9776396 | biostudies-literature
| S-EPMC6722019 | biostudies-literature
| S-EPMC8157348 | biostudies-literature
| S-EPMC6342787 | biostudies-literature
| S-EPMC6261302 | biostudies-literature
2022-10-07 | GSE214760 | GEO