Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures.


ABSTRACT:

Aims

Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI.

Methods and result

A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation.

Conclusion

During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar.

SUBMITTER: Lemoine MD 

PROVIDER: S-EPMC11363872 | biostudies-literature | 2024 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures.

Lemoine Marc D MD   Obergassel Julius J   Jaeckle Sandro S   Nies Moritz M   Taraba Sophia S   Mencke Celine C   Rieß Jan J   My Ilaria I   Rottner Laura L   Moser Fabian F   Ismaili Djemail D   Reißmann Bruno B   Ouyang Feifan F   Kirchhof Paulus P   Rillig Andreas A   Metzner Andreas A  

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 20240801 9


<h4>Aims</h4>Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI.<h4>Methods and result</h4>A total of 550 consecutivel  ...[more]

Similar Datasets

| S-EPMC10751845 | biostudies-literature
| S-EPMC10902096 | biostudies-literature
| S-EPMC10331428 | biostudies-literature
| S-EPMC9935020 | biostudies-literature
| S-EPMC10558367 | biostudies-literature
| S-EPMC10241727 | biostudies-literature
| S-EPMC10103571 | biostudies-literature
| S-EPMC8427383 | biostudies-literature
| S-EPMC6962741 | biostudies-literature
| S-EPMC8174287 | biostudies-literature