Utilizing fully-automated 3D organ segmentation for hepatic steatosis assessment with CT attenuation-based parameters.


ABSTRACT:

Objectives

To investigate the clinical utility of fully-automated 3D organ segmentation in assessing hepatic steatosis on pre-contrast and post-contrast CT images using magnetic resonance spectroscopy (MRS)-proton density fat fraction (PDFF) as reference standard.

Materials and methods

This retrospective study analyzed 362 adult potential living liver donors with abdominal CT scans and MRS-PDFF. Using a deep learning-based tool, mean volumetric CT attenuation of the liver and spleen were measured on pre-contrast (liver(L)_pre and spleen(S)_pre) and post-contrast (L_post and S_post) images. Agreements between volumetric and manual region-of-interest (ROI)-based measurements were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performances of volumetric parameters (L_pre, liver-minus-spleen (L-S)_pre, L_post, and L-S_post) were evaluated for detecting MRS-PDFF ≥ 5% and ≥ 10% using receiver operating characteristic (ROC) curve analysis and compared with those of ROI-based parameters.

Results

Among the 362 subjects, 105 and 35 had hepatic steatosis with MRS-PDFF ≥ 5% and ≥ 10%, respectively. Volumetric and ROI-based measurements revealed ICCs of 0.974, 0.825, 0.992, and 0.962, with mean differences of -4.2 HU, -3.4 HU, -1.2 HU, and -7.7 HU for L_pre, S_pre, L_post, and S_post, respectively. Volumetric L_pre, L-S_pre, L_post, and L-S_post yielded areas under the ROC curve of 0.813, 0.813, 0.734, and 0.817 for MRS-PDFF ≥ 5%; and 0.901, 0.915, 0.818, and 0.868 for MRS-PDFF ≥ 10%, comparable with those of ROI-based parameters (0.735-0.818; and 0.816-0.895, Ps = 0.228-0.911).

Conclusion

Automated 3D segmentation of the liver and spleen in CT scans can provide volumetric CT attenuation-based parameters to detect and grade hepatic steatosis, applicable to pre-contrast and post-contrast images.

Clinical relevance statement

Volumetric CT attenuation-based parameters of the liver and spleen, obtained through automated segmentation tools from pre-contrast or post-contrast CT scans, can efficiently detect and grade hepatic steatosis, making them applicable for large population data collection.

Key points

• Automated organ segmentation enables the extraction of CT attenuation-based parameters for the target organ. • Volumetric liver and spleen CT attenuation-based parameters are highly accurate in hepatic steatosis assessment. • Automated CT measurements from pre- or post-contrast imaging show promise for hepatic steatosis screening in large cohorts.

SUBMITTER: Yoo J 

PROVIDER: S-EPMC11364604 | biostudies-literature | 2024 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Utilizing fully-automated 3D organ segmentation for hepatic steatosis assessment with CT attenuation-based parameters.

Yoo Jeongin J   Joo Ijin I   Jeon Sun Kyung SK   Park Junghoan J   Yoon Soon Ho SH  

European radiology 20240223 9


<h4>Objectives</h4>To investigate the clinical utility of fully-automated 3D organ segmentation in assessing hepatic steatosis on pre-contrast and post-contrast CT images using magnetic resonance spectroscopy (MRS)-proton density fat fraction (PDFF) as reference standard.<h4>Materials and methods</h4>This retrospective study analyzed 362 adult potential living liver donors with abdominal CT scans and MRS-PDFF. Using a deep learning-based tool, mean volumetric CT attenuation of the liver and sple  ...[more]

Similar Datasets

| S-EPMC11252222 | biostudies-literature
| S-EPMC8082409 | biostudies-literature
| S-EPMC7794235 | biostudies-literature
| S-EPMC7979624 | biostudies-literature
| S-EPMC10881508 | biostudies-literature
| S-EPMC6692233 | biostudies-literature
| S-EPMC10948387 | biostudies-literature
| S-EPMC7289260 | biostudies-literature
| S-EPMC6327279 | biostudies-literature
| S-EPMC5752269 | biostudies-literature