Unknown

Dataset Information

0

Linear-After-The-Exponential (LATE)-PCR: primer design criteria for high yields of specific single-stranded DNA and improved real-time detection.


ABSTRACT: Traditional asymmetric PCR uses conventional PCR primers at unequal concentrations to generate single-stranded DNA. This method, however, is difficult to optimize, often inefficient, and tends to promote nonspecific amplification. An alternative approach, Linear-After-The-Exponential (LATE)-PCR, solves these problems by using primer pairs deliberately designed for use at unequal concentrations. The present report systematically examines the primer design parameters that affect the exponential and linear phases of LATE-PCR amplification. In particular, we investigated how altering the concentration-adjusted melting temperature (Tm) of the limiting primer (TmL) relative to that of the excess primer (TmX) affects both amplification efficiency and specificity during the exponential phase of LATE-PCR. The highest reaction efficiency and specificity were observed when TmL - TmX 5 degrees C. We also investigated how altering TmX relative to the higher Tm of the double-stranded amplicon (TmA) affects the rate and extent of linear amplification. Excess primers with TmX closer to TmA yielded higher rates of linear amplification and stronger signals from a hybridization probe. These design criteria maximize the yield of specific single-stranded DNA products and make LATE-PCR more robust and easier to implement. The conclusions were validated by using primer pairs that amplify sequences within the cystic fibrosis transmembrane regulator (CFTR) gene, mutations of which are responsible for cystic fibrosis.

SUBMITTER: Pierce KE 

PROVIDER: S-EPMC1150831 | biostudies-literature | 2005 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Linear-After-The-Exponential (LATE)-PCR: primer design criteria for high yields of specific single-stranded DNA and improved real-time detection.

Pierce Kenneth E KE   Sanchez J Aquiles JA   Rice John E JE   Wangh Lawrence J LJ  

Proceedings of the National Academy of Sciences of the United States of America 20050603 24


Traditional asymmetric PCR uses conventional PCR primers at unequal concentrations to generate single-stranded DNA. This method, however, is difficult to optimize, often inefficient, and tends to promote nonspecific amplification. An alternative approach, Linear-After-The-Exponential (LATE)-PCR, solves these problems by using primer pairs deliberately designed for use at unequal concentrations. The present report systematically examines the primer design parameters that affect the exponential an  ...[more]

Similar Datasets

| S-EPMC1533996 | biostudies-literature
| S-EPMC357030 | biostudies-literature
| S-EPMC2018630 | biostudies-literature
| S-EPMC1347517 | biostudies-literature
| S-EPMC7330846 | biostudies-literature
| S-EPMC3495711 | biostudies-literature
| S-EPMC168931 | biostudies-literature
| S-EPMC5009631 | biostudies-literature
| S-EPMC2453112 | biostudies-literature
2007-12-20 | GSE9929 | GEO