Exon array CGH: detection of copy-number changes at the resolution of individual exons in the human genome.


ABSTRACT: The development of high-throughput screening methods such as array-based comparative genome hybridization (array CGH) allows screening of the human genome for copy-number changes. Current array CGH strategies have limits of resolution that make detection of small (less than a few tens of kilobases) gains or losses of genomic DNA difficult to identify. We report here a significant improvement in the resolution of array CGH, with the development of an array platform that utilizes single-stranded DNA array elements to accurately measure copy-number changes of individual exons in the human genome. Using this technology, we screened 31 patient samples across an array containing a total of 162 exons for five disease genes and detected copy-number changes, ranging from whole-gene deletions and duplications to single-exon deletions and duplications, in 100% of the cases. Our data demonstrate that it is possible to screen the human genome for copy-number changes with array CGH at a resolution that is 2 orders of magnitude higher than that previously reported.

SUBMITTER: Dhami P 

PROVIDER: S-EPMC1199365 | biostudies-literature | 2005 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Exon array CGH: detection of copy-number changes at the resolution of individual exons in the human genome.

Dhami Pawandeep P   Coffey Alison J AJ   Abbs Stephen S   Vermeesch Joris R JR   Dumanski Jan P JP   Woodward Karen J KJ   Andrews Robert M RM   Langford Cordelia C   Vetrie David D  

American journal of human genetics 20050308 5


The development of high-throughput screening methods such as array-based comparative genome hybridization (array CGH) allows screening of the human genome for copy-number changes. Current array CGH strategies have limits of resolution that make detection of small (less than a few tens of kilobases) gains or losses of genomic DNA difficult to identify. We report here a significant improvement in the resolution of array CGH, with the development of an array platform that utilizes single-stranded D  ...[more]

Similar Datasets

| S-EPMC3158569 | biostudies-literature
| S-EPMC2920185 | biostudies-literature
| S-EPMC2811007 | biostudies-other
| S-EPMC3907382 | biostudies-literature
| S-EPMC1994778 | biostudies-literature
| S-EPMC2909945 | biostudies-literature
| S-EPMC2442610 | biostudies-literature
| S-EPMC4478553 | biostudies-literature
| S-EPMC3250374 | biostudies-literature
| S-EPMC3329635 | biostudies-literature