Project description:ObjectiveThe colloid osmotic pressure (COP) of plasma and interstitial fluid play important roles in transvascular fluid exchange. COP values for monitoring fluid balance in healthy and sick children have not been established. This study set out to determine reference values of COP in healthy children.Materials and methodsCOP in plasma and interstitial fluid harvested from nylon wicks was measured in 99 healthy children from 2 to 10 years of age. Nylon wicks were implanted subcutaneously in arm and leg while patients were sedated and intubated during a minor surgical procedure. COP was analyzed in a colloid osmometer designed for small fluid samples.ResultsThe mean plasma COP in all children was 25.6 ± 3.3 mmHg. Arbitrary division of children in four different age groups, showed no significant difference in plasma or interstitial fluid COP values for patients less than 8 years, whereas patients of 8-10 years had significant higher COP both in plasma and interstitial fluid. There were no gender difference or correlation between COP in interstitial fluid sampled from arm and leg and no significant effect on interstitial COP of gravity. Prolonged implantation time did not affect interstitial COP.ConclusionPlasma and interstitial COP in healthy children are comparable to adults and COP seems to increase with age in children. Knowledge of the interaction between colloid osmotic forces can be helpful in diseases associated with fluid imbalance and may be crucial in deciding different fluid treatment options.Trial registrationClinicalTrials.gov NCT01044641.
Project description:BackgroundIn clinical states associated with systemic oxidative stress (OS) and inflammation such as chronic kidney disease (CKD), oxidative modifications of serum albumin impair its quantification, resulting in apparent hypoalbuminemia. As the maintenance of oncotic pressure/colloid osmotic pressure (COP) is a major function of albumin, this study examined the impact of albumin oxidation on COP, both in-vivo and in-vitro.MethodsPatients with proteinuria and patients on chronic hemodialysis (HD) with systemic inflammation and OS were enrolled. Blood samples were collected from 134 subjects: 32 healthy controls (HC), proteinuric patients with high (n = 17) and low (n = 31) systemic inflammation and from 54 patients on chronic hemodialysis (HD) with the highest levels of OS and inflammation.ResultsIn-vitro oxidized albumin showed significantly higher COP values than non-oxidized albumin at identical albumin levels. In vivo, in hypoalbuminemic HD patients with the highest OS and inflammation, COP values were also higher than expected for the low albumin levels. The contribution to COP by other prevalent plasma proteins, such as fibrinogen and immunoglobulins was negligible. We imply that the calculation of COP based on albumin levels should be revisited in face of OS and inflammation. Hence, in hypoalbuminemic proteinuric patients with systemic OS and inflammation the assumption of low COP should be verified by its measurements.
Project description:Background and objectivesColloid osmotic pressure (COP) is a principal determinant of intravascular fluid homeostasis and a pillar of fluid therapy and transfusion. Transfusion-associated circulatory overload (TACO) is a leading complication of transfusion, and COP could be responsible for recruiting additional fluid. Study objective was to measure COP of blood products as well as investigate the effects of product concentration and storage lesion on COP.Materials and methodsThree units of each product were sampled longitudinally. COP was measured directly as well as the determinants thereof albumin and total protein. Conventional blood products, that is red blood cell (RBC), fresh-frozen plasma (FFP) and platelet concentrates (PLTs), were compared with their concentrated counterparts: volume-reduced RBCs, hyperconcentrated PLTs, and fully and partially reconstituted lyophilized plasma (prLP). Fresh and maximally stored products were measured to determine changes in protein and COP. We calculated potential volume load (PVL) to estimate volume recruited using albumin's water binding per product.ResultsColloid osmotic pressure varies widely between conventional products (RBCs, 1·9; PLTs, 7·5; and FFP, 20·1 mmHg); however, all are hypooncotic compared with human plasma COP (25·4 mmHg). Storage lesion did not increase COP. Concentrating RBCs and PLTs did not increase COP; only prLP showed a supraphysiological COP of 47·3 mm Hg. The PVL of concentrated products was lower than conventional products.ConclusionColloid osmotic pressure of conventional products was low. Therefore, third-space fluid recruitment is an unlikely mechanism in TACO. Concentrated products had a lower calculated fluid load and may prevent TACO. Finally, storage did not significantly increase oncotic pressure of blood products.
Project description:To measure colloid osmotic pressure in interstitial fluid (COP(i)) from human subcutaneous tissue with the modified wick technique in order to determine influence of topical application of anaesthetics, dry vs. wet wick and implantation time on COP(i).In 50 healthy volunteers interstitial fluid (IF) was collected by subcutaneous implantation of multi-filamentous nylon wicks. Study subjects were allocated to two groups; one for comparing COP(i) obtained from dry and saline soaked wicks, and one for comparing COP(i) from unanaesthetized skin, and skin after application of a eutectic mixture of local anaesthetic (EMLA®, Astra Zeneca) cream. IF was sampled from the skin of the shoulders, and implantation time was 30, 60, 75, 90 and 120 min. Colloid osmotic pressure was measured with a colloid osmometer. Pain assessment during the procedure was compared for EMLA cream and no topical anaesthesia using a visual analogue scale (VAS) in a subgroup of 10 subjects.There were no significant differences between COP(i) obtained from dry compared to wet wicks, except that the values after 75 and 90 min. were somewhat higher for the dry wicks. Topical anaesthesia with EMLA cream did not affect COP(i) values. COP(i) decreased from 30 to 75 min. of implantation (23.2 ± 4.4 mmHg to 19.6 ± 2.9 mmHg, p = 0.008) and subsequently tended to increase until 120 min. EMLA cream resulted in significant lower VAS score for the procedure.COP(i) from subcutaneous tissue was easily obtained and fluid harvesting was well tolerated when topical anaesthetic was used. The difference in COP(i) assessed by dry and wet wicks between 75 min. and 90 min. of implantation was in accordance with previous reports. The use of topical analgesia did not influence COP(i) and topical analgesia may make the wick technique more acceptable for subjects who dislike technical procedures, including children.ClinicalTrials.gov NCT01044979.
Project description:Why do people give to strangers? We propose that people trust and give more to those whose emotional expressions match how they ideally want to feel ("ideal affect match"). European Americans and Koreans played multiple trials of the Dictator Game with recipients who varied in emotional expression (excited, calm), race (White, Asian) and sex (male, female). Consistent with their culture's valued affect, European Americans trusted and gave more to excited than calm recipients, whereas Koreans trusted and gave more to calm than excited recipients. These findings held regardless of recipient race and sex. We then used fMRI to probe potential affective and mentalizing mechanisms. Increased activity in the nucleus accumbens (associated with reward anticipation) predicted giving, as did decreased activity in the right temporo-parietal junction (rTPJ; associated with reduced belief prediction error). Ideal affect match decreased rTPJ activity, suggesting that people may trust and give more to strangers whom they perceive to share their affective values.
Project description:Interventions: Group 1:Total fluid input = physiological requirement + preoperative cumulative loss + continuing loss + third space loss + compensatory volume expansion;Group 2:Goal-directed fluid therapy based on stroke volume variation;Group 3:Goal-directed fluid therapy based on stroke volume variation and plasma colloid osmotic pressure
Primary outcome(s): Indicators of changes in lung function;Postoperative pulmonary complications occurring within 7 days after surgery;Lung injury score
Study Design: Parallel
Project description:Using Escherichia coli as a model organism, we studied how water is recruited by a bacterial swarm. A previous analysis of trajectories of small air bubbles revealed a stream of fluid flowing in a clockwise direction ahead of the swarm. A companion study suggested that water moves out of the agar into the swarm in a narrow region centered ? 30 ?m from the leading edge of the swarm and then back into the agar (at a smaller rate) in a region centered ? 120 ?m back from the leading edge. Presumably, these flows are driven by changes in osmolarity. Here, we utilized green/red fluorescent liposomes as reporters of osmolarity to verify this hypothesis. The stream of fluid that flows in front of the swarm contains osmolytes. Two distinct regions are observed inside the swarm near its leading edge: an outer high-osmolarity band (? 30 mOsm higher than the agar baseline) and an inner low-osmolarity band (isotonic or slightly hypotonic to the agar baseline). This profile supports the fluid-flow model derived from the drift of air bubbles and provides new (to our knowledge) insights into water maintenance in bacterial swarms. High osmotic pressure at the leading edge of the swarm extracts water from the underlying agar and promotes motility. The osmolyte is of high molecular weight and probably is lipopolysaccharide.
Project description:One of the puzzling phenomena in philanthropy is that people can show strong compassion for identified individual victims but remain unmoved by catastrophes that affect large numbers of victims. Two prominent findings in research on charitable giving reflect this idiosyncrasy: The (1) identified victim and (2) victim number effects. The first of these suggests that identifying victims increases donations and the second refers to the finding that people's willingness to donate often decreases as the number of victims increases. While these effects have been documented in the literature, their underlying psychological processes need further study. We propose a model in which identified victim and victim number effects operate through different cognitive and affective mechanisms. In two experiments we present empirical evidence for such a model and show that different affective motivations (donor-focused vs. victim-focused feelings) are related to the cognitive processes of impact judgments and mental imagery. Moreover, we argue that different mediation pathways exist for identifiability and victim number effects.
Project description:An estimated 6.3 billion metric tons of post-consumer polymer waste has been produced, with the majority (79%) in landfills or the environment. Recycling methods that utilize these waste polymers could attenuate their environmental impact. For many polymers, recycling via mechanical processes is not feasible and these materials are destined for landfills or incineration. One salient example is the superabsorbent material used in diapers and feminine hygiene products, which contain crosslinked sodium polyacrylates. Here we report an open-loop recycling method for these materials that involves (i) decrosslinking via hydrolysis, (ii) an optional chain-shortening via sonication, and (iii) functionalizing via Fischer esterification. The resulting materials exhibit low-to-medium storage and loss moduli, and as such, are applicable as general-purpose adhesives. A life cycle assessment demonstrates that the adhesives synthesized via this approach outcompete the same materials derived from petroleum feedstocks on nearly every metric, including carbon dioxide emissions and cumulative energy demand.