Unknown

Dataset Information

0

Shedding and reversion of oral polio vaccine type 3 in Mexican vaccinees: comparison of mutant analysis by PCR and enzyme cleavage to a real-time PCR assay.


ABSTRACT: A uracil-to-cytosine mutation at nucleotide position 472 of oral poliovirus vaccine type 3 (OPV3) contributes to the development of vaccine-associated paralytic poliomyelitis (VAPP). To analyze OPV3 shedding patterns, we previously used the multistep method of mutant analysis by PCR and enzyme cleavage (MAPREC). This involves conventional reverse transcription-PCR to detect OPV3, followed by a restriction digest to quantify position 472 reversion. Real-time PCR detects and quantifies nucleic acid as PCR occurs and avoids postreaction processing. The goal of this study was to compare a real-time PCR method to MAPREC. Seventy-three stool samples from Mexican OPV recipients underwent the reverse transcription-PCR step of MAPREC and real-time PCR. Real-time PCR identified 23% more OPV3-positive samples than conventional reverse transcription-PCR. When reversion was compared, the revertant proportion (RP), defined as the percentage of revertants in a sample, differed by < or =10% in 21/25 (84%) samples. The four samples differing by >10% were obtained within 5 days of OPV administration. The real-time PCR assay identified samples with an RP of > or =85% with 94% sensitivity and 86% specificity compared to MAPREC. The mean difference in RP between the two methods was 3.6% (95% confidence interval, -0.3 to 7.5%). Real-time PCR methods reliably detect OPV3, and reversion estimates correlate more consistently with MAPREC when OPV3 reversion rates are high. Detecting VAPP-related mutations by real-time PCR is rapid and efficient and can be useful in monitoring ongoing global polio eradication efforts.

SUBMITTER: Gnanashanmugam D 

PROVIDER: S-EPMC1951214 | biostudies-literature | 2007 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Shedding and reversion of oral polio vaccine type 3 in Mexican vaccinees: comparison of mutant analysis by PCR and enzyme cleavage to a real-time PCR assay.

Gnanashanmugam Devasena D   Falkovitz-Halpern Meira S MS   Dodge Anthony A   Fang Melanie M   Wong Lisa J LJ   Esparza Melissa M   Hammon Rebecca R   Rivas-Merelles Enrique E EE   Santos Jose I JI   Maldonado Yvonne Y  

Journal of clinical microbiology 20070620 8


A uracil-to-cytosine mutation at nucleotide position 472 of oral poliovirus vaccine type 3 (OPV3) contributes to the development of vaccine-associated paralytic poliomyelitis (VAPP). To analyze OPV3 shedding patterns, we previously used the multistep method of mutant analysis by PCR and enzyme cleavage (MAPREC). This involves conventional reverse transcription-PCR to detect OPV3, followed by a restriction digest to quantify position 472 reversion. Real-time PCR detects and quantifies nucleic aci  ...[more]

Similar Datasets

| S-EPMC3122635 | biostudies-literature
| S-EPMC6206120 | biostudies-literature
| S-EPMC7566161 | biostudies-literature
| S-EPMC9045443 | biostudies-literature
| S-EPMC3049956 | biostudies-literature
| S-EPMC6206113 | biostudies-literature
| S-EPMC1698312 | biostudies-literature
| S-EPMC6422504 | biostudies-literature
| S-EPMC6522622 | biostudies-literature
| S-EPMC7946408 | biostudies-literature