Unknown

Dataset Information

Skeletal muscle oxygen saturation does not estimate mixed venous oxygen saturation in patients with severe left heart failure and additional severe sepsis or septic shock.


ABSTRACT:

Introduction

Low cardiac output states such as left heart failure are characterized by preserved oxygen extraction ratio, which is in contrast to severe sepsis. Near infrared spectroscopy (NIRS) allows noninvasive estimation of skeletal muscle tissue oxygenation (StO2). The aim of the study was to determine the relationship between StO2 and mixed venous oxygen saturation (SvO2) in patients with severe left heart failure with or without additional severe sepsis or septic shock.

Methods

Sixty-five patients with severe left heart failure due to primary heart disease were divided into two groups: groups A (n = 24) and B (n = 41) included patients without and with additional severe sepsis/septic shock, respectively. Thenar muscle StO2 was measured using NIRS in the patients and i

SUBMITTER: Podbregar M 