An oxygen scavenging system for improvement of dye stability in single-molecule fluorescence experiments.


ABSTRACT: The application of single-molecule fluorescence techniques to complex biological systems places demands on the performance of single fluorophores. We present an enzymatic oxygen scavenging system for improved dye stability in single-molecule experiments. We compared the previously described protocatechuic acid/protocatechuate-3,4-dioxygenase system to the currently employed glucose oxidase/catalase system. Under standardized conditions, we observed lower dissolved oxygen concentrations with the protocatechuic acid/protocatechuate-3,4-dioxygenase system. Furthermore, we observed increased initial lifetimes of single Cy3, Cy5, and Alexa488 fluorophores. We further tested the effects of chemical additives in this system. We found that biological reducing agents increase both the frequency and duration of blinking events of Cy5, an effect that scales with reducing potential. We observed increased stability of Cy3 and Alexa488 in the presence of the antioxidants ascorbic acid and n-propyl gallate. This new O(2)-scavenging system should have wide application for single-molecule fluorescence experiments.

SUBMITTER: Aitken CE 

PROVIDER: S-EPMC2242739 | biostudies-literature | 2008 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

An oxygen scavenging system for improvement of dye stability in single-molecule fluorescence experiments.

Aitken Colin Echeverría CE   Marshall R Andrew RA   Puglisi Joseph D JD  

Biophysical journal 20071005 5


The application of single-molecule fluorescence techniques to complex biological systems places demands on the performance of single fluorophores. We present an enzymatic oxygen scavenging system for improved dye stability in single-molecule experiments. We compared the previously described protocatechuic acid/protocatechuate-3,4-dioxygenase system to the currently employed glucose oxidase/catalase system. Under standardized conditions, we observed lower dissolved oxygen concentrations with the  ...[more]

Similar Datasets

| S-EPMC3403312 | biostudies-literature
| S-EPMC2904532 | biostudies-literature
| S-EPMC5898730 | biostudies-literature
| S-EPMC3878298 | biostudies-literature
| S-EPMC2820649 | biostudies-literature
| S-EPMC2764082 | biostudies-other
| S-EPMC4805879 | biostudies-other
| S-EPMC5407667 | biostudies-literature
| S-EPMC6016803 | biostudies-other
| S-EPMC5975723 | biostudies-literature