Unknown

Dataset Information

0

Application of at-line two-dimensional liquid chromatography-mass spectrometry for identification of small hydrophilic angiotensin I-inhibiting peptides in milk hydrolysates.


ABSTRACT: A two-dimensional chromatographic method with mass spectrometric detection has been developed for identification of small, hydrophilic angiotensin I-inhibiting peptides in enzymatically hydrolysed milk proteins. The method involves the further separation of the poorly retained hydrophilic fraction from a standard C(18) reversed-phase column on a hydrophilic interaction liquid chromatography (HILIC) column. The latter column is specifically designed for the separation of hydrophilic compounds. Narrow fractions collected from the HILIC column were analysed for their angiotensin I-converting enzyme (ACE) inhibiting potential in an at-line assay. Fractions showing significant inhibition of ACE were analysed by LC-MS for structure elucidation. With this method the main peptides responsible for ACE-inhibition in the hydrophilic part of a milk hydrolysate could be determined. The ACE-inhibiting peptides RP, AP, VK, EK, and EW explained more than 85% of ACE-inhibition by the hydrophilic fraction.

SUBMITTER: van Platerink CJ 

PROVIDER: S-EPMC2324126 | biostudies-literature | 2008 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Application of at-line two-dimensional liquid chromatography-mass spectrometry for identification of small hydrophilic angiotensin I-inhibiting peptides in milk hydrolysates.

van Platerink Chris J CJ   Janssen Hans-Gerd M HG   Haverkamp Johan J  

Analytical and bioanalytical chemistry 20080409 1


A two-dimensional chromatographic method with mass spectrometric detection has been developed for identification of small, hydrophilic angiotensin I-inhibiting peptides in enzymatically hydrolysed milk proteins. The method involves the further separation of the poorly retained hydrophilic fraction from a standard C(18) reversed-phase column on a hydrophilic interaction liquid chromatography (HILIC) column. The latter column is specifically designed for the separation of hydrophilic compounds. Na  ...[more]

Similar Datasets

| S-EPMC5805588 | biostudies-literature
| S-EPMC8786911 | biostudies-literature
| S-EPMC10704588 | biostudies-literature
| S-EPMC4737587 | biostudies-literature
| S-EPMC7197904 | biostudies-literature
| S-EPMC10932214 | biostudies-literature
| S-EPMC6500481 | biostudies-literature
| S-EPMC7996953 | biostudies-literature
| S-EPMC8943687 | biostudies-literature