Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: a preclinical study.


ABSTRACT: Safe and effective device closure of ventricular septal defects remains a challenge. We have developed a transcardiac approach to close ventricular septal defects using a patch delivery and fixation system that can be secured under real-time three-dimensional echocardiographic guidance.In Yorkshire pigs (n = 8) a coring device was introduced into the left ventricle through a purse-string suture placed on the left ventricular apex, and a muscular ventricular septal defect was created. The patch deployment device containing a 20-mm polyester patch was advanced toward the ventricular septal defect through another purse-string suture on the left ventricular apex, and the patch was deployed under real-time three-dimensional echocardiographic guidance. The anchor delivery device was then introduced into the left ventricle through the first purse-string suture. Nitinol anchors to attach the patch around the ventricular septal defect were deployed under real-time three-dimensional echocardiographic guidance. After patch attachment, residual shunts were sought by means of two-dimensional and three-dimensional color Doppler echocardiography. The heart was then excised, and the septum with the patch was inspected.A ventricular septal defect was created in the midventricular (n = 4), anterior (n = 2), and apical (n = 2) septum. The mean size was 9.8 mm (8.2-12.0 mm), as determined by means of two-dimensional color Doppler scanning. The ventricular septal defects were completely closed in 7 animals. In one a 2.4-mm residual shunt was identified. No anatomic structures were compromised.Beating-heart perventricular muscular ventricular septal defect closure without cardiopulmonary bypass can be successfully achieved by using a catheter-based patch delivery and fixation system under real-time three-dimensional echocardiographic guidance. This approach might be a better alternative to cardiac surgery or transcatheter device closure.

SUBMITTER: Vasilyev NV 

PROVIDER: S-EPMC2350207 | biostudies-literature | 2008 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: a preclinical study.

Vasilyev Nikolay V NV   Melnychenko Ivan I   Kitahori Kazuo K   Freudenthal Franz P FP   Phillips Alistair A   Kozlik-Feldmann Rainer R   Salgo Ivan S IS   del Nido Pedro J PJ   Bacha Emile A EA  

The Journal of thoracic and cardiovascular surgery 20080301 3


<h4>Objectives</h4>Safe and effective device closure of ventricular septal defects remains a challenge. We have developed a transcardiac approach to close ventricular septal defects using a patch delivery and fixation system that can be secured under real-time three-dimensional echocardiographic guidance.<h4>Methods</h4>In Yorkshire pigs (n = 8) a coring device was introduced into the left ventricle through a purse-string suture placed on the left ventricular apex, and a muscular ventricular sep  ...[more]

Similar Datasets

| S-EPMC7336984 | biostudies-literature
| S-EPMC7175755 | biostudies-literature
| S-EPMC2938468 | biostudies-literature
| S-EPMC8543163 | biostudies-literature
| S-EPMC5408532 | biostudies-other
| S-EPMC6794751 | biostudies-literature
| S-EPMC8592680 | biostudies-literature
| S-EPMC7552712 | biostudies-literature
| S-EPMC4590191 | biostudies-literature