Comparison of the internal energy deposition of Venturi-assisted electrospray ionization and a Venturi-assisted array of micromachined ultrasonic electrosprays (AMUSE).


ABSTRACT: The internal energy deposition of a Venturi-assisted array of micromachined ultrasonic electrosprays (AMUSE), with and without the application of a DC charging potential, is compared with equivalent experiments for Venturi-assisted electrospray ionization (ESI) using the "survival yield" method on a series of para-substituted benzylpyridinium salts. Under conditions previously shown to provide maximum ion yields for standard compounds, the observed mean internal energies were nearly identical (1.93-2.01 eV). Operation of AMUSE without nitrogen flow to sustain the air amplifier focusing effect generated energetically colder ions with mean internal energies that were up to 39% lower than those for ESI. A balance between improved ion transfer, adequate desolvation, and favorable ion energetics was achieved by selection of optimum operational ranges for the parameters that most strongly influence the ion population: the air amplifier gas flow rate and API capillary temperature. Examination of the energy landscapes obtained for combinations of these parameters showed that a low internal energy region (

SUBMITTER: Hampton CY 

PROVIDER: S-EPMC2563429 | biostudies-literature | 2008 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of the internal energy deposition of Venturi-assisted electrospray ionization and a Venturi-assisted array of micromachined ultrasonic electrosprays (AMUSE).

Hampton Christina Y CY   Silvestri Catherine J CJ   Forbes Thomas P TP   Varady Mark J MJ   Meacham J Mark JM   Fedorov Andrei G AG   Degertekin F Levent FL   Fernández Facundo M FM  

Journal of the American Society for Mass Spectrometry 20080628 9


The internal energy deposition of a Venturi-assisted array of micromachined ultrasonic electrosprays (AMUSE), with and without the application of a DC charging potential, is compared with equivalent experiments for Venturi-assisted electrospray ionization (ESI) using the "survival yield" method on a series of para-substituted benzylpyridinium salts. Under conditions previously shown to provide maximum ion yields for standard compounds, the observed mean internal energies were nearly identical (1  ...[more]

Similar Datasets

| S-EPMC2543123 | biostudies-literature
| S-EPMC6937789 | biostudies-literature
| S-EPMC10582076 | biostudies-literature
| S-EPMC6470568 | biostudies-literature
| S-EPMC3750536 | biostudies-literature
| S-EPMC4899806 | biostudies-literature
| S-EPMC8708802 | biostudies-literature
| S-EPMC8284694 | biostudies-literature
| S-EPMC5653407 | biostudies-literature
| S-EPMC5007172 | biostudies-literature