Unknown

Dataset Information

0

Studying copy number variations using a nanofluidic platform.


ABSTRACT: Copy number variations (CNVs) in the human genome are conventionally detected using high-throughput scanning technologies, such as comparative genomic hybridization and high-density single nucleotide polymorphism (SNP) microarrays, or relatively low-throughput techniques, such as quantitative polymerase chain reaction (PCR). All these approaches are limited in resolution and can at best distinguish a twofold (or 50%) difference in copy number. We have developed a new technology to study copy numbers using a platform known as the digital array, a nanofluidic biochip capable of accurately quantitating genes of interest in DNA samples. We have evaluated the digital array's performance using a model system, to show that this technology is exquisitely sensitive, capable of differentiating as little as a 15% difference in gene copy number (or between 6 and 7 copies of a target gene). We have also analyzed commercial DNA samples for their CYP2D6 copy numbers and confirmed that our results were consistent with those obtained independently using conventional techniques. In a screening experiment with breast cancer and normal DNA samples, the ERBB2 gene was found to be amplified in about 35% of breast cancer samples. The use of the digital array enables accurate measurement of gene copy numbers and is of significant value in CNV studies.

SUBMITTER: Qin J 

PROVIDER: S-EPMC2566873 | biostudies-literature | 2008 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Studying copy number variations using a nanofluidic platform.

Qin Jian J   Jones Robert C RC   Ramakrishnan Ramesh R  

Nucleic acids research 20080818 18


Copy number variations (CNVs) in the human genome are conventionally detected using high-throughput scanning technologies, such as comparative genomic hybridization and high-density single nucleotide polymorphism (SNP) microarrays, or relatively low-throughput techniques, such as quantitative polymerase chain reaction (PCR). All these approaches are limited in resolution and can at best distinguish a twofold (or 50%) difference in copy number. We have developed a new technology to study copy num  ...[more]

Similar Datasets

| S-EPMC5886540 | biostudies-literature
2009-02-18 | GSE14856 | GEO
| S-EPMC5110597 | biostudies-literature
| S-EPMC2731494 | biostudies-literature
| S-EPMC3997817 | biostudies-literature
2009-02-18 | GSE14745 | GEO
2009-02-18 | GSE14742 | GEO
2009-02-18 | GSE14740 | GEO
2010-05-06 | E-GEOD-14856 | biostudies-arrayexpress
| S-EPMC2588508 | biostudies-other