Ontology highlight
ABSTRACT: Purpose
To determine the incremental benefit of combined endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging, as compared with endorectal MR imaging alone, for sextant localization of peripheral zone (PZ) prostate cancer.Materials and methods
This prospective multicenter study, conducted by the American College of Radiology Imaging Network (ACRIN) from February 2004 to June 2005, was institutional review board approved and HIPAA compliant. Research associates were required to follow consent guidelines approved by the Office for Human Research Protection and established by the institutional review boards. One hundred thirty-four patients with biopsy-proved prostate adenocarcinoma and scheduled to undergo radical prostatectomy were recruited at seven institutions. T1-weighted, T2-weighted, and spectroscopic MR sequences were performed at 1.5 T by using a pelvic phased-array coil in combination with an endorectal coil. Eight readers independently rated the likelihood of the presence of PZ cancer in each sextant by using a five-point scale-first on MR images alone and later on combined MR-MR spectroscopic images. Areas under the receiver operating characteristic curve (AUCs) were calculated with sextant as the unit of analysis. The presence or absence of cancer at centralized histopathologic evaluation of prostate specimens was the reference standard. Reader-specific receiver operating characteristic curves for values obtained with MR imaging alone and with combined MR imaging-MR spectroscopic imaging were developed. The AUCs were estimated by using Mann-Whitney statistics and appropriate 95% confidence intervals.Results
Complete data were available for 110 patients (mean age, 58 years; range, 45-72 years). MR imaging alone and combined MR imaging-MR spectroscopic imaging had similar accuracy in PZ cancer localization (AUC, 0.60 vs 0.58, respectively; P > .05). AUCs for individual readers were 0.57-0.63 for MR imaging alone and 0.54-0.61 for combined MR imaging-MR spectroscopic imaging.Conclusion
In patients who undergo radical prostatectomy, the accuracy of combined 1.5-T endorectal MR imaging-MR spectroscopic imaging for sextant localization of PZ prostate cancer is equal to that of MR imaging alone.
SUBMITTER: Weinreb JC
PROVIDER: S-EPMC2663583 | biostudies-literature | 2009 Apr
REPOSITORIES: biostudies-literature
Radiology 20090401 1
<h4>Purpose</h4>To determine the incremental benefit of combined endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging, as compared with endorectal MR imaging alone, for sextant localization of peripheral zone (PZ) prostate cancer.<h4>Materials and methods</h4>This prospective multicenter study, conducted by the American College of Radiology Imaging Network (ACRIN) from February 2004 to June 2005, was institutional review board approved and HIPAA compliant. Research associates ...[more]