Anatomy of a wrong diagnosis: false sinus venosus atrial septal defect.


ABSTRACT: In contrast with transthoracic echocardiography, transesophageal echocardiography provides a sure way to make the diagnosis of sinus venosus atrial septal defect; on the other hand this abnormality is more complex than that seen with the secundum atrial septal defect, and inexperienced operators may fail to recognize properly the defect. In front of a high reported sensitivity using transesophageal echocardiography, specificity is difficult to assess, due to possible underreporting of diagnostic errors. We describe a false positive diagnosis of sinus venosus atrial septal defect, in the setting of enlarged right chambers of the heart because of pressure overload. Modified anatomy of the heart, together with the presence of a prominent linear structure(probably Eustachian Valve) and an incomplete examination in this case made image interpretation very prone to misinterpretation. In this anatomical setting transesophageal longitudinal "bicaval" view may be sub-optimal for examining the atrial septum, potentially showing false images that need to be known for correct image interpretation. Nonetheless, a scan plane taken more accurately at the superior level would have demonstrated/excluded the pathognomonic feature of sinus venosus atrial septal defect in the high atrial septum, between the fatty limbus and the inferior aspect of the right pulmonary artery; moreover TEE allows morphological information about the posterior structures of the heart that need to be investigated in detail for a complete diagnosis.

SUBMITTER: Gaibazzi N 

PROVIDER: S-EPMC270092 | biostudies-literature | 2003

REPOSITORIES: biostudies-literature

altmetric image

Publications

Anatomy of a wrong diagnosis: false sinus venosus atrial septal defect.

Gaibazzi Nicola N   Montresor Graziano G   Poeta Maria Luisa ML  

Cardiovascular ultrasound 20031107


In contrast with transthoracic echocardiography, transesophageal echocardiography provides a sure way to make the diagnosis of sinus venosus atrial septal defect; on the other hand this abnormality is more complex than that seen with the secundum atrial septal defect, and inexperienced operators may fail to recognize properly the defect. In front of a high reported sensitivity using transesophageal echocardiography, specificity is difficult to assess, due to possible underreporting of diagnostic  ...[more]

Similar Datasets

| S-EPMC9120852 | biostudies-literature
| S-EPMC8766320 | biostudies-literature
| S-EPMC4039816 | biostudies-other
| S-EPMC6891039 | biostudies-literature
| S-EPMC6175141 | biostudies-literature
| S-EPMC8343453 | biostudies-literature
| S-EPMC4900353 | biostudies-literature
| S-EPMC3895076 | biostudies-literature
| S-EPMC8127027 | biostudies-literature