Auto-adjusting positive airway pressure in children with sickle cell anemia: results of a phase I randomized controlled trial.


ABSTRACT: Low nocturnal oxygen saturation (SpO(2)) is implicated in complications of Sickle Cell Anemia (SCA). Twenty-four children with SCA were randomized to receive overnight auto-adjusting continuous positive airway pressure (auto-CPAP) with supplemental oxygen, if required, to maintain SpO(2) >or=94% or as controls. We assessed adherence, safety, sleep parameters, cognition and pain. Twelve participants randomized to auto-CPAP (3 with oxygen) showed improvement in Apnea/Hypopnea Index (p<0.001), average desaturation events >3%/hour (p=0.02), mean nocturnal SpO(2) (p=0.02) and cognition. Primary efficacy endpoint (Processing Speed Index) showed no group differences (p=0.67), but a second measure of processing speed and attention (Cancellation) improved in those receiving treatment (p=0.01). No bone marrow suppression, rebound pain or serious adverse event resulting from auto-CPAP use was observed. Six weeks of auto-CPAP therapy is feasible and safe in children with SCA, significantly improving sleep-related breathing disorders and at least one aspect of cognition.

SUBMITTER: Marshall MJ 

PROVIDER: S-EPMC2704312 | biostudies-literature | 2009 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Auto-adjusting positive airway pressure in children with sickle cell anemia: results of a phase I randomized controlled trial.

Marshall Melanie J MJ   Bucks Romola S RS   Hogan Alexandra M AM   Hambleton Ian R IR   Height Susan E SE   Dick Moira C MC   Kirkham Fenella J FJ   Rees David C DC  

Haematologica 20090701 7


Low nocturnal oxygen saturation (SpO(2)) is implicated in complications of Sickle Cell Anemia (SCA). Twenty-four children with SCA were randomized to receive overnight auto-adjusting continuous positive airway pressure (auto-CPAP) with supplemental oxygen, if required, to maintain SpO(2) >or=94% or as controls. We assessed adherence, safety, sleep parameters, cognition and pain. Twelve participants randomized to auto-CPAP (3 with oxygen) showed improvement in Apnea/Hypopnea Index (p<0.001), aver  ...[more]

Similar Datasets

| S-EPMC4237517 | biostudies-literature
| S-EPMC6622520 | biostudies-literature
| S-EPMC3047289 | biostudies-literature
| S-EPMC3787918 | biostudies-literature
| S-EPMC4567557 | biostudies-literature
| S-EPMC3365086 | biostudies-literature
| S-EPMC7847310 | biostudies-literature
| S-EPMC7252515 | biostudies-literature
| S-EPMC4918996 | biostudies-literature
| S-EPMC8158763 | biostudies-literature