Quantitative microplate-based respirometry with correction for oxygen diffusion.


ABSTRACT: Respirometry using modified cell culture microplates offers an increase in throughput and a decrease in biological material required for each assay. Plate based respirometers are susceptible to a range of diffusion phenomena; as O(2) is consumed by the specimen, atmospheric O(2) leaks into the measurement volume. Oxygen also dissolves in and diffuses passively through the polystyrene commonly used as a microplate material. Consequently the walls of such respirometer chambers are not just permeable to O(2) but also store substantial amounts of gas. O(2) flux between the walls and the measurement volume biases the measured oxygen consumption rate depending on the actual [O(2)] gradient. We describe a compartment model-based correction algorithm to deconvolute the biological oxygen consumption rate from the measured [O(2)]. We optimize the algorithm to work with the Seahorse XF24 extracellular flux analyzer. The correction algorithm is biologically validated using mouse cortical synaptosomes and liver mitochondria attached to XF24 V7 cell culture microplates, and by comparison to classical Clark electrode oxygraph measurements. The algorithm increases the useful range of oxygen consumption rates, the temporal resolution, and durations of measurements. The algorithm is presented in a general format and is therefore applicable to other respirometer systems.

SUBMITTER: Gerencser AA 

PROVIDER: S-EPMC2727168 | biostudies-literature | 2009 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative microplate-based respirometry with correction for oxygen diffusion.

Gerencser Akos A AA   Neilson Andy A   Choi Sung W SW   Edman Ursula U   Yadava Nagendra N   Oh Richard J RJ   Ferrick David A DA   Nicholls David G DG   Brand Martin D MD  

Analytical chemistry 20090801 16


Respirometry using modified cell culture microplates offers an increase in throughput and a decrease in biological material required for each assay. Plate based respirometers are susceptible to a range of diffusion phenomena; as O(2) is consumed by the specimen, atmospheric O(2) leaks into the measurement volume. Oxygen also dissolves in and diffuses passively through the polystyrene commonly used as a microplate material. Consequently the walls of such respirometer chambers are not just permeab  ...[more]

Similar Datasets

| S-EPMC3411749 | biostudies-literature
| S-EPMC8383715 | biostudies-literature
| S-EPMC4572531 | biostudies-literature
| S-EPMC4839650 | biostudies-literature
| S-EPMC5241082 | biostudies-literature
2019-02-25 | GSE119271 | GEO
| S-EPMC3030233 | biostudies-literature
| S-EPMC7355239 | biostudies-literature
| S-EPMC6142173 | biostudies-literature
| S-EPMC3175489 | biostudies-literature