Unknown

Dataset Information

0

MIFlowCyt: the minimum information about a Flow Cytometry Experiment.


ABSTRACT: A fundamental tenet of scientific research is that published results are open to independent validation and refutation. Minimum data standards aid data providers, users, and publishers by providing a specification of what is required to unambiguously interpret experimental findings. Here, we present the Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) standard, stating the minimum information required to report flow cytometry (FCM) experiments. We brought together a cross-disciplinary international collaborative group of bioinformaticians, computational statisticians, software developers, instrument manufacturers, and clinical and basic research scientists to develop the standard. The standard was subsequently vetted by the International Society for Advancement of Cytometry (ISAC) Data Standards Task Force, Standards Committee, membership, and Council. The MIFlowCyt standard includes recommendations about descriptions of the specimens and reagents included in the FCM experiment, the configuration of the instrument used to perform the assays, and the data processing approaches used to interpret the primary output data. MIFlowCyt has been adopted as a standard by ISAC, representing the FCM scientific community including scientists as well as software and hardware manufacturers. Adoptionof MIFlowCyt by the scientific and publishing communities will facilitate third-party understanding and reuse of FCM data.

SUBMITTER: Lee JA 

PROVIDER: S-EPMC2773297 | biostudies-literature | 2008 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

MIFlowCyt: the minimum information about a Flow Cytometry Experiment.

Lee Jamie A JA   Spidlen Josef J   Boyce Keith K   Cai Jennifer J   Crosbie Nicholas N   Dalphin Mark M   Furlong Jeff J   Gasparetto Maura M   Goldberg Michael M   Goralczyk Elizabeth M EM   Hyun Bill B   Jansen Kirstin K   Kollmann Tobias T   Kong Megan M   Leif Robert R   McWeeney Shannon S   Moloshok Thomas D TD   Moore Wayne W   Nolan Garry G   Nolan John J   Nikolich-Zugich Janko J   Parrish David D   Purcell Barclay B   Qian Yu Y   Selvaraj Biruntha B   Smith Clayton C   Tchuvatkina Olga O   Wertheimer Anne A   Wilkinson Peter P   Wilson Christopher C   Wood James J   Zigon Robert R   Scheuermann Richard H RH   Brinkman Ryan R RR  

Cytometry. Part A : the journal of the International Society for Analytical Cytology 20081001 10


A fundamental tenet of scientific research is that published results are open to independent validation and refutation. Minimum data standards aid data providers, users, and publishers by providing a specification of what is required to unambiguously interpret experimental findings. Here, we present the Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) standard, stating the minimum information required to report flow cytometry (FCM) experiments. We brought together a cross-discip  ...[more]

Similar Datasets

| S-EPMC6123892 | biostudies-other
| S-EPMC6035131 | biostudies-literature
| S-EPMC4120647 | biostudies-literature
| S-EPMC3867282 | biostudies-literature
2018-09-26 | GSE120446 | GEO
| S-EPMC5444268 | biostudies-literature
| 2406350 | ecrin-mdr-crc
| S-EPMC3060130 | biostudies-literature
| S-EPMC3717030 | biostudies-literature
2018-09-21 | GSE120221 | GEO