Unknown

Dataset Information

0

Single bead-based electrochemical biosensor.


ABSTRACT: A simple, robust, single bead-based electrochemical biosensor was fabricated and characterized. The sensor's working electrode consists of an electrochemically etched platinum wire, with a nominal diameter of 25 microm, hermetically heat-fusion sealed in a pulled glass capillary (micropipette). The sealing process does not require any epoxy or glue. A commercially available, densely functionalized agarose bead was mounted on the tip of the etched platinum wire. The use of a pre-functionalized bead eliminates the tedious and complicated surface functionalization process that is often the bottleneck in the development of electrochemical biosensors. We report on the use of a biotin agarose bead-based, micropipette, electrochemical (Bio-BMP) biosensor to monitor H(2)O(2) concentration and the use of a streptavidin bead-based, micropipette, electrochemical (SA-BMP) biosensor to detect DNA amplicons. The Bio-BMP biosensor's response increased linearly as the H(2)O(2) concentration increased in the range from 1 x 10(-6) to 1.2 x10(-4)M with a detection limit of 5 x 10(-7)M. The SA-BMP was able to detect the amplicons of 1pg DNA template of B. Cereus bacteria, thus providing better detection sensitivity than conventional gel-based electropherograms.

SUBMITTER: Liu C 

PROVIDER: S-EPMC2784131 | biostudies-literature | 2009 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Single bead-based electrochemical biosensor.

Liu Changchun C   Schrlau Michael G MG   Bau Haim H HH  

Biosensors & bioelectronics 20090828 4


A simple, robust, single bead-based electrochemical biosensor was fabricated and characterized. The sensor's working electrode consists of an electrochemically etched platinum wire, with a nominal diameter of 25 microm, hermetically heat-fusion sealed in a pulled glass capillary (micropipette). The sealing process does not require any epoxy or glue. A commercially available, densely functionalized agarose bead was mounted on the tip of the etched platinum wire. The use of a pre-functionalized be  ...[more]

Similar Datasets

| S-EPMC2948235 | biostudies-literature
| S-EPMC9313153 | biostudies-literature
| S-EPMC5385560 | biostudies-literature
| S-EPMC6956173 | biostudies-literature
| S-EPMC8433164 | biostudies-literature
| S-EPMC9049677 | biostudies-literature
| S-EPMC10620918 | biostudies-literature
| S-EPMC8946795 | biostudies-literature
| S-EPMC7180619 | biostudies-literature
| S-EPMC9880620 | biostudies-literature