Unknown

Dataset Information

0

Variability of intraocular pressure measurements in observation participants in the ocular hypertension treatment study.


ABSTRACT:

Purpose

To describe variability of intraocular pressure (IOP) measurements within the same eye and between right and left eyes over a 60-month period in participants in the Ocular Hypertension Treatment Study.

Design

Analysis of data from a prospective, randomized clinical trial.

Participants

Eight hundred ten participants randomized to the observation group.

Methods

Intraocular pressure measurements were obtained at the baseline visit and every 6 months thereafter. Pearson correlation coefficients were calculated for IOP measurements in the same eye between visits and for IOP measurements between right and left eyes of participants at each visit. Differences in IOP measurements between visits are reported in percent change (>15%, >20%, and >30%) and in millimeters of mercury (<3 mmHg, 3-5 mmHg, and >5 mmHg). The effects of regression to the mean, consistency in time of day, and sequence of IOP measurement of right and left eyes were examined.

Main outcome measures

Correlation of IOP measurements between consecutive 6-month visits.

Results

The correlation of IOP measurements within the same eye between consecutive visits was r = 0.62, whereas the correlation of IOP measurements between right and left eyes at the same visit was r = 0.72. Thirteen percent of eyes had >20% change in IOP between consecutive visits. Sixty-six percent of eyes had a change in IOP within 3 mmHg, and 10% of eyes had a change in IOP >5 mmHg between visits. Eyes with a higher baseline IOP had a lower IOP at 6 months. There was a stronger correlation of IOP measured within 2 hours of the time of day between visits (r = 0.56) than >2 hours apart (r = 0.39). IOP of the right eye, which was measured first, was 0.3+/-2.8 mmHg higher than the left eye.

Conclusions

The variability of IOP measurements in the same eye between consecutive visits is moderate and is greater than the variability of IOP measurements between right and left eyes at the same visit. Factors affecting the variability of IOP measurement include regression to the mean, time of day, and measurement order. Knowledge of variability in IOP and its measurements may help clinicians establish a more accurate baseline IOP, target IOP, and assessment of medication effect.

SUBMITTER: Bhorade AM 

PROVIDER: S-EPMC2790916 | biostudies-literature | 2009 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Variability of intraocular pressure measurements in observation participants in the ocular hypertension treatment study.

Bhorade Anjali M AM   Gordon Mae O MO   Wilson Brad B   Weinreb Robert N RN   Kass Michael A MA  

Ophthalmology 20090225 4


<h4>Purpose</h4>To describe variability of intraocular pressure (IOP) measurements within the same eye and between right and left eyes over a 60-month period in participants in the Ocular Hypertension Treatment Study.<h4>Design</h4>Analysis of data from a prospective, randomized clinical trial.<h4>Participants</h4>Eight hundred ten participants randomized to the observation group.<h4>Methods</h4>Intraocular pressure measurements were obtained at the baseline visit and every 6 months thereafter.  ...[more]

Similar Datasets

| S-EPMC3618610 | biostudies-literature
| S-EPMC8695549 | biostudies-literature
| S-EPMC3966140 | biostudies-literature
| S-EPMC7585392 | biostudies-literature
| S-EPMC3342789 | biostudies-literature
| S-EPMC6865321 | biostudies-literature
| S-EPMC5624590 | biostudies-literature
| S-EPMC7171415 | biostudies-literature
| S-EPMC8802016 | biostudies-literature
| S-EPMC10035833 | biostudies-literature