Unknown

Dataset Information

0

Electrochemical sensor for multiplex biomarkers detection.


ABSTRACT: Multiplexing assay of biomarkers at the point-of-care is an elusive goal for molecular diagnostics.Here, we report an electrochemical (EC) sensor for oral cancer detection based on the simultaneous detection of two salivary biomarkers: interleukin (IL)-8 mRNA and IL-8 protein.Under the multiplexing mode, the limit of detection of salivary IL-8 mRNA reaches to 3.9 fM and 7.4 pg/mL for IL-8 protein in saliva. Multiplex assay of these 2 biomarkers directly from 28 cancer and 28 matched control saliva samples shows significant difference between the two groups. From the receiver operating characteristic analysis, the EC sensor yields around 90% sensitivity and specificity for both IL-8 mRNA and IL-8 protein, which are very close to the data measured by traditional assays (ELISA and PCR) with the same group of saliva. Combined IL-8 mRNA and protein show better AUC compared with single biomarker.We show, for the first time, concurrently multiplexing detection of salivary mRNA and protein biomarkers using point-of-care EC sensor.

SUBMITTER: Wei F 

PROVIDER: S-EPMC2799532 | biostudies-literature | 2009 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrochemical sensor for multiplex biomarkers detection.

Wei Fang F   Patel Prabhudas P   Liao Wei W   Chaudhry Kishore K   Zhang Lei L   Arellano-Garcia Martha M   Hu Shen S   Elashoff David D   Zhou Hui H   Shukla Shilin S   Shah Franky F   Ho Chih-Ming CM   Wong David T DT  

Clinical cancer research : an official journal of the American Association for Cancer Research 20090609 13


<h4>Purpose</h4>Multiplexing assay of biomarkers at the point-of-care is an elusive goal for molecular diagnostics.<h4>Experimental design</h4>Here, we report an electrochemical (EC) sensor for oral cancer detection based on the simultaneous detection of two salivary biomarkers: interleukin (IL)-8 mRNA and IL-8 protein.<h4>Results</h4>Under the multiplexing mode, the limit of detection of salivary IL-8 mRNA reaches to 3.9 fM and 7.4 pg/mL for IL-8 protein in saliva. Multiplex assay of these 2 bi  ...[more]

Similar Datasets

| S-EPMC8659774 | biostudies-literature
| S-EPMC5579540 | biostudies-literature
| S-EPMC4389811 | biostudies-other
| S-EPMC7412172 | biostudies-literature
| S-EPMC8709324 | biostudies-literature
| S-EPMC8746692 | biostudies-literature
| S-EPMC5479482 | biostudies-literature
| S-EPMC4549174 | biostudies-literature
| S-EPMC8989844 | biostudies-literature
| S-EPMC9599216 | biostudies-literature