Scanned-probe detection of electron spin resonance from a nitroxide spin probe.


ABSTRACT: We report an approach that extends the applicability of ultrasensitive force-gradient detection of magnetic resonance to samples with spin-lattice relaxation times (T (1)) as short as a single cantilever period. To demonstrate the generality of the approach, which relies on detecting either cantilever frequency or phase, we used it to detect electron spin resonance from a T (1) = 1 ms nitroxide spin probe in a thin film at 4.2 K and 0.6 T. By using a custom-fabricated cantilever with a 4 microm-diameter nickel tip, we achieve a magnetic resonance sensitivity of 400 Bohr magnetons in a 1 Hz bandwidth. A theory is presented that quantitatively predicts both the lineshape and the magnitude of the observed cantilever frequency shift as a function of field and cantilever-sample separation. Good agreement was found between nitroxide T (1) 's measured mechanically and inductively, indicating that the cantilever magnet is not an appreciable source of spin-lattice relaxation here. We suggest that the new approach has a number of advantages that make it well suited to push magnetic resonance detection and imaging of nitroxide spin labels in an individual macromolecule to single-spin sensitivity.

SUBMITTER: Moore EW 

PROVIDER: S-EPMC2799694 | biostudies-literature | 2009 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Scanned-probe detection of electron spin resonance from a nitroxide spin probe.

Moore Eric W EW   Lee SangGap S   Hickman Steven A SA   Wright Sarah J SJ   Harrell Lee E LE   Borbat Peter P PP   Freed Jack H JH   Marohn John A JA  

Proceedings of the National Academy of Sciences of the United States of America 20091214 52


We report an approach that extends the applicability of ultrasensitive force-gradient detection of magnetic resonance to samples with spin-lattice relaxation times (T (1)) as short as a single cantilever period. To demonstrate the generality of the approach, which relies on detecting either cantilever frequency or phase, we used it to detect electron spin resonance from a T (1) = 1 ms nitroxide spin probe in a thin film at 4.2 K and 0.6 T. By using a custom-fabricated cantilever with a 4 microm-  ...[more]

Similar Datasets

| S-EPMC3981471 | biostudies-literature
| S-EPMC4096354 | biostudies-literature
| S-EPMC3952064 | biostudies-literature
| S-EPMC4426033 | biostudies-literature
| S-EPMC4639813 | biostudies-literature
| S-EPMC2766176 | biostudies-other
| S-EPMC2731549 | biostudies-literature
| S-EPMC4735623 | biostudies-literature
| S-EPMC3631243 | biostudies-other
| S-EPMC5628910 | biostudies-literature