The cost-effectiveness of continuous glucose monitoring in type 1 diabetes.


ABSTRACT:

Objective

Continuous glucose monitoring (CGM) has been found to improve glucose control in type 1 diabetic patients. We estimated the cost-effectiveness of CGM versus standard glucose monitoring in type 1 diabetes. RESEARCH DESIGN AND METHODS This societal cost-effectiveness analysis (CEA) was conducted in trial populations in which CGM has produced a significant glycemic benefit (A1C >or=7.0% in a cohort of adults aged >or=25 years and A1C <7.0% in a cohort of all ages). Trial data were integrated into a simulation model of type 1 diabetes complications. The main outcome was the cost per quality-adjusted life-year (QALY) gained.

Results

During the trials, CGM patients experienced an immediate quality-of-life benefit (A1C >or=7.0% cohort: 0.70 quality-adjusted life-weeks [QALWs], P = 0.49; A1C <7.0% cohort: 1.39 QALWs, P = 0.04) and improved glucose control. In the long-term, CEA for the A1C >or=7.0% cohort, CGM was projected to reduce the lifetime probability of microvascular complications; the average gain in QALYs was 0.60. The incremental cost-effectiveness ratio (ICER) was $98,679/QALY (95% CI -60,000 [fourth quadrant] to -87,000 [second quadrant]). For the A1C <7.0% cohort, the average gain in QALYs was 1.11. The ICER was $78,943/QALY (15,000 [first quadrant] to -291,000 [second quadrant]). If the benefit of CGM had been limited to the long-term effects of improved glucose control, the ICER would exceed $700,000/QALY. If test strip use had been two per day with CGM long term the ICER for CGM would improve significantly.

Conclusions

Long-term projections indicate that CGM is cost-effective among type 1 diabetic patients at the $100,000/QALY threshold, although considerable uncertainty surrounds these estimates.

SUBMITTER: Huang ES 

PROVIDER: S-EPMC2875436 | biostudies-literature | 2010 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Objective</h4>Continuous glucose monitoring (CGM) has been found to improve glucose control in type 1 diabetic patients. We estimated the cost-effectiveness of CGM versus standard glucose monitoring in type 1 diabetes. RESEARCH DESIGN AND METHODS This societal cost-effectiveness analysis (CEA) was conducted in trial populations in which CGM has produced a significant glycemic benefit (A1C >or=7.0% in a cohort of adults aged >or=25 years and A1C <7.0% in a cohort of all ages). Trial data were  ...[more]

Similar Datasets

| S-EPMC3180394 | biostudies-literature
| S-EPMC5961392 | biostudies-literature
| S-EPMC9310589 | biostudies-literature
| S-EPMC9663778 | biostudies-literature
| S-EPMC9064487 | biostudies-literature
| S-EPMC3064030 | biostudies-literature
| S-EPMC2797966 | biostudies-literature
| S-EPMC6900078 | biostudies-literature
| S-EPMC9607728 | biostudies-literature
| S-EPMC2802601 | biostudies-literature