Unknown

Dataset Information

0

Dually Fluorescent Sensing of pH and Dissolved Oxygen Using a Membrane Made from Polymerizable Sensing Monomers.


ABSTRACT: Using a thermal polymerization approach and polymerizable pH and oxygen sensing monomers with green and red emission spectra, respectively, new pH, oxygen, and their dual sensing membranes were prepared using poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) as a matrix. The sensors were grafted on acrylate-modified quartz glass and characterized under different pH values, oxygen concentrations, ion strengths, temperatures and cell culture media. The pH and oxygen sensors were excited using the same excitation wavelength and exhibited well-separated emission spectra. The pH-sensing films showed good response over the pH range 5.5 to 8.5, corresponding to pK(a) values in the biologically-relevant range between 6.9 and 7.1. The oxygen-sensing films exhibited linear Stern-Volmer quenching responses to dissolved oxygen. As the sensing membranes were prepared using thermally initiated polymerization of sensing moiety-containing monomers, no leaching of the sensors from the membranes to buffers or medium was observed. This advantageous characteristic accounts in part for the sensors' biocompatibility without apparent toxicity to HeLa cells after 40 hours incubation. The dual-sensing membrane was used to measure pH and dissolved oxygen simultaneously. The measured results correlated with the set-point values.

SUBMITTER: Tian Y 

PROVIDER: S-EPMC2882062 | biostudies-literature | 2010 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dually Fluorescent Sensing of pH and Dissolved Oxygen Using a Membrane Made from Polymerizable Sensing Monomers.

Tian Yanqing Y   Shumway Bradley R BR   Youngbull A Cody AC   Li Yongzhong Y   Jen Alex K-Y AK   Johnson Roger H RH   Meldrum Deirdre R DR  

Sensors and actuators. B, Chemical 20100601 2


Using a thermal polymerization approach and polymerizable pH and oxygen sensing monomers with green and red emission spectra, respectively, new pH, oxygen, and their dual sensing membranes were prepared using poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) as a matrix. The sensors were grafted on acrylate-modified quartz glass and characterized under different pH values, oxygen concentrations, ion strengths, temperatures and cell culture media. The pH and oxygen sensors were excited using  ...[more]

Similar Datasets

| S-EPMC6989363 | biostudies-literature
| S-EPMC3758920 | biostudies-literature
| S-EPMC6171317 | biostudies-literature
2019-02-14 | GSE110723 | GEO
| S-EPMC5335539 | biostudies-literature
| S-EPMC11280439 | biostudies-literature
| S-EPMC2861433 | biostudies-literature
| S-EPMC2844653 | biostudies-literature
| S-EPMC7878508 | biostudies-literature
| S-EPMC7641513 | biostudies-literature