Unknown

Dataset Information

0

Using power spectrum analysis to evaluate (18)O-water labeling data acquired from low resolution mass spectrometers.


ABSTRACT: We describe a method for ratio estimations in (18)O-water labeling experiments acquired from low resolution isotopically resolved data. The method is implemented in a software package specifically designed for use in experiments making use of zoom-scan mode data acquisition. Zoom-scan mode data allow commonly used ion trap mass spectrometers to attain isotopic resolution, which makes them amenable to use in labeling schemes such as (18)O-water labeling, but algorithms and software developed for high resolution instruments may not be appropriate for the lower resolution data acquired in zoom-scan mode. The use of power spectrum analysis is proposed as a general approach that may be uniquely suited to these data types. The software implementation uses a power spectrum to remove high-frequency noise and band-filter contributions from coeluting species of differing charge states. From the elemental composition of a peptide sequence, we generate theoretical isotope envelopes of heavy-light peptide pairs in five different ratios; these theoretical envelopes are correlated with the filtered experimental zoom scans. To automate peptide quantification in high-throughput experiments, we have implemented our approach in a computer program, MassXplorer. We demonstrate the application of MassXplorer to two model mixtures of known proteins and to a complex mixture of mouse kidney cortical extract. Comparison with another algorithm for ratio estimations demonstrates the increased precision and automation of MassXplorer.

SUBMITTER: Sadygov RG 

PROVIDER: S-EPMC2922858 | biostudies-literature | 2010 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Using power spectrum analysis to evaluate (18)O-water labeling data acquired from low resolution mass spectrometers.

Sadygov Rovshan G RG   Zhao Yingxin Y   Haidacher Sigmund J SJ   Starkey Jonathan M JM   Tilton Ronald G RG   Denner Larry L  

Journal of proteome research 20100801 8


We describe a method for ratio estimations in (18)O-water labeling experiments acquired from low resolution isotopically resolved data. The method is implemented in a software package specifically designed for use in experiments making use of zoom-scan mode data acquisition. Zoom-scan mode data allow commonly used ion trap mass spectrometers to attain isotopic resolution, which makes them amenable to use in labeling schemes such as (18)O-water labeling, but algorithms and software developed for  ...[more]

Similar Datasets

| S-EPMC3946283 | biostudies-literature
| S-EPMC7672638 | biostudies-literature
| S-EPMC3070069 | biostudies-literature
| S-EPMC7845485 | biostudies-literature
| S-EPMC7494442 | biostudies-literature
| S-EPMC3334416 | biostudies-literature
| S-EPMC7017751 | biostudies-literature
| S-EPMC8167932 | biostudies-literature
| S-EPMC4779083 | biostudies-literature
| S-EPMC5492990 | biostudies-literature